DOI 10.4293/108680811x13125733356918
Laparoendoscopic single site (LESS) splenectomy with a conventional laparoscope and instruments.
Аннотация
BACKGROUND AND
OBJECTIVES
We present 2 cases of laparoendoscopic single site surgery (LESS) splenectomy performed with a conventional laparoscope and instruments, and the use of a novel internal retraction device.
METHODS
One patient underwent LESS splenectomy for idiopathic thrombocytopenia purpura (ITP), and a pediatric patient with sickle cell disease underwent LESS splenectomy and cholecystectomy. In each case, a 2-cm vertical incision was made within the confines of the umbilical ring, and a SILS port (Covidien, Norwalk CT) inserted. A 5-mm, 30-degree laparoscope and standard 5-mm instruments were used. After isolation of the splenic hilum, one 5-mm trocar of the SILS port was upsized to 12mm, and a laparoscopic stapler was used to divide the splenic artery and vein. An internal retractor consisting of a laparoscopic bulldog clamp with a hook attachment was used to retract the gallbladder, and to secure the specimen retrieval bag during splenic extraction, which eliminated the need for a fourth trocar.
RESULTS
Total operative time was 160 minutes for the LESS splenectomy, and 216 minutes for the LESS splenectomy and cholecystectomy. Both procedures were successfully completed with conventional instrumentation and a SILS port, without the need for additional incisions or trocars. No complications occurred, and both patients had an uneventful recovery.
CONCLUSIONS
LESS splenectomy is a feasible procedure that can be performed safely. Although articulating instruments and laparoscopes may offer advantages, they are not necessary for performing LESS splenectomy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.