MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mri.2015.10.018

Медицинская библиотека · Magnetic resonance imaging · 2015

2D AMESING multi-echo (31)P-MRSI of the liver at 7T allows transverse relaxation assessment and T2-weighted averaging for improved SNR.

Runge Jurgen Henk, van der Kemp Wybe J M, Klomp Dennis W J, Luijten Peter R, Nederveen Aart J, Stoker Jaap

СтатьяПеревод в очереди

Аннотация

PURPOSE: Liver diseases are a major global health concern often requiring invasive assessment by needle biopsy. (31)P magnetic resonance spectroscopic imaging (MRSI) allows non-invasive probing of important liver metabolites. Recently, the adiabatic multi-echo spectroscopic imaging sequence with spherical k-space sampling (AMESING) was introduced at 7T, enabling acquisition of T2 information. T2-weighed averaging of the multiple echoes improves signal-to-noise ratio (SNR). The purpose of our study was to implement AMESING MRSI of the liver at 3T and 7T, derive localized T2 information and compare T2-weighted average spectra in terms of SNR.

METHODS

Ten male volunteers underwent 2D AMESING MRSI at 3T and 7T after a minimum four-hour fast. SNR was calculated for PC, PE, Pi, GPE, GPC and α-ATP using maximum peak amplitudes and the SD of the noise. Metabolite peak ratios were calculated after fitting in jMRUI. SNR values and peak ratios were compared with the Wilcoxon signed-rank test.

RESULTS

For the first time liver metabolites' T2 values at 7T were measured: PE (55.6±3.5 ms), PC (51.2±2.3 ms), Pi (46.4±1.1 ms), GPE (44.0±0.8 ms), GPC (50.4±0.8 ms) and α-ATP (18.2±0.4 ms). SNR gain using T2-weighted averaging at 7T resulted in a 1.2× SNR gain. In conjunction with higher field strength and improved coil set-up T2-weighted averaging at 7T allowed a total 3.2× SNR gain compared to 3T FID-only.

CONCLUSION

AMESING 2D MRSI of the liver at 7T provides T2 values that allow T2-weighted averaging of data from multiple echoes resulting in improved SNR.

Для цитирования: Runge Jurgen Henk, van der Kemp Wybe J M, Klomp Dennis W J, Luijten Peter R, Nederveen Aart J, Stoker Jaap. 2D AMESING multi-echo (31)P-MRSI of the liver at 7T allows transverse relaxation assessment and T2-weighted averaging for improved SNR.. Magnetic resonance imaging. 2015. DOI: 10.1016/j.mri.2015.10.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.