MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acra.2025.03.039

Медицинская библиотека · Academic radiology · 2025

External Validation of an Artificial Intelligence Algorithm Using Biparametric MRI and Its Simulated Integration with Conventional PI-RADS for Prostate Cancer Detection.

Belue Mason J, Mukhtar Vaneeza, Ram Roopa, Gokden Neriman, Jose Joe, Massey Jackson L, Biben Emily, Buddha Suryakala, Langford Timothy, Shah Sumit, Harmon Stephanie A, Turkbey Baris, Aydin Ahmet Murat

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: Prostate imaging reporting and data systems (PI-RADS) experiences considerable variability in inter-reader performance. Artificial Intelligence (AI) algorithms were suggested to provide comparable performance to PI-RADS for assessing prostate cancer (PCa) risk, albeit tested in highly selected cohorts. This study aimed to assess an AI algorithm for PCa detection in a clinical practice setting and simulate integration of the AI model with PI-RADS for assessment of indeterminate PI-RADS 3 lesions.

PATIENTS AND

METHODS

This retrospective cohort study externally validated a biparametric MRI-based AI model for PCa detection in a consecutive cohort of patients who underwent prostate MRI and subsequently targeted and systematic prostate biopsy at a urology clinic between January 2022 and March 2024. Radiologist interpretations followed PI-RADS v2.1, and biopsies were conducted per PI-RADS scores. The previously developed AI model provided lesion segmentations and cancer probability maps which were compared to biopsy results. Additionally, we conducted a simulation to adjust biopsy thresholds for index PI-RADS category 3 studies, where AI predictions within these studies upgraded them to PI-RADS category 4.

RESULTS

Among 144 patients with a median age of 70 years and PSA density of 0.17ng/mL/cc, AI's sensitivity for detection of PCa (86.6%) and clinically significant PCa (csPCa, 88.4%) was comparable to radiologists (85.7%, p=0.84, and 89.5%, p=0.80, respectively). The simulation combining radiologist and AI evaluations improved clinically significant PCa sensitivity by 5.8% (p=0.025). The combination of AI, PI-RADS and PSA density provided the best diagnostic performance for csPCa (area under the curve [AUC]=0.76).

CONCLUSION

The AI algorithm demonstrated comparable PCa detection rates to PI-RADS. The combination of AI with radiologist interpretation improved sensitivity and could be instrumental in assessment of low-risk and indeterminate PI-RADS lesions. The role of AI in PCa screening remains to be further elucidated.

Для цитирования: Belue Mason J, Mukhtar Vaneeza, Ram Roopa, Gokden Neriman, Jose Joe, Massey Jackson L, Biben Emily, Buddha Suryakala, Langford Timothy, Shah Sumit, Harmon Stephanie A, Turkbey Baris, Aydin Ahmet Murat. External Validation of an Artificial Intelligence Algorithm Using Biparametric MRI and Its Simulated Integration with Conventional PI-RADS for Prostate Cancer Detection.. Academic radiology. 2025. DOI: 10.1016/j.acra.2025.03.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.