DOI 10.1111/pace.13855

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2020

Predictors of successful ultrasound-guided lead implantation.

Ahmed Asim S, Gilge Jasen L, Clark Brad A, Shah Ankur, Bagga Shiv, Padanilam Mathew S, Prystowsky Eric N, Joshi Sandeep A, Nair Girish V, Patel Parin J

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Technical advances have improved the safety of cardiac implantable electronic device (CIED) insertion, but periprocedural complications persist. Despite ultrasound (US) guidance for vascular access being feasible and exhibiting shorter fluoroscopy times, it is not widely adopted for insertion of CIEDs. Thus, we studied the use of US for CIED insertion to (1) quantify the success rate of venous cannulation, (2) identify predictors of failed cannulation, and (3) quantify the rate of complications using US guidance.

METHODS

We studied 166 consecutive patients who underwent US-guided CIED implantation. Anatomic parameters of the axillary vein were measured. The primary outcome was success (group 1) or failure (group 2) to obtain vascular access utilizing US guidance. Secondary outcomes included pneumothorax and hematoma.

RESULTS

Successful US-guided cannulation occurred in 154 of 166 patients (93%). No patient had a pneumothorax. Hematoma occurred in 1 of 166 patients (0.01%). Group 2 exhibited higher male proportion at 11 of 12 (92%) compared with 94 of 154 (61%) in group 1 (P = .03), increased vein depth at 3.84 versus 2.85 cm (P = .003), more right-sided implants (P = .03), higher weight at 104.6 versus 85.3 kg (P = .017), higher body mass index at 35.6 versus 29.2 kg/m2 (P = .049), and higher body surface area at 2.24 versus 1.99 m2 (P = .013). Other parameters were statistically nonsignificant. In multivariate analysis, vein depth remained significantly associated with failure.

CONCLUSION

Using US guidance for CIED implantation is successful in the vast majority (93%) of patients. Rare cases of unsuccessful cannulation were associated with right-sided implants and increased venous depth.

Для цитирования: Ahmed Asim S, Gilge Jasen L, Clark Brad A, Shah Ankur, Bagga Shiv, Padanilam Mathew S, Prystowsky Eric N, Joshi Sandeep A, Nair Girish V, Patel Parin J. Predictors of successful ultrasound-guided lead implantation.. Pacing and clinical electrophysiology : PACE. 2020. DOI: 10.1111/pace.13855.