INTRODUCTION

Infection and exposure of the implant may occur in 1-12% of patients operated on for arthroplasty or osteosynthesis. Variables such as tissue viability, presence of infection, exposure of osteosynthesis material and patient-related factors contribute to the lack of general consensus regarding the management of these defects.

MATERIALS AND

METHODS

Between January 1999 and January 2001, six patients were treated for complex soft-tissue defects following various orthopaedic procedures at the Department of Plastic Surgery in the Slotervaartziekenhuis in Amsterdam, a rheuma-orthopaedic orientated hospital. All patients were initially treated by radical debridement and vacuum-assisted closure (VAC) system of the wound. After 1 week, this was followed by transplantation of a pedicled or free flap to cover the defect. We studied the medical history, initial orthopaedic procedure, wound treatment, transplanted flap and outcome of plastic surgery in this group.

RESULTS

Plastic surgical intervention led to wound closure in all cases. In only one case was the osteosynthesis material removed because of osteomyelitis.

CONCLUSIONS

We conclude that the earlier coverage with vital tissue is obtained, the lower the incidence of infection. Early consultation by a plastic surgeon will increase a positive outcome of treatment of complex tissue defects.

Для цитирования: Bihariesingh V J, Stolarczyk Ewa M, Karim Refaat B, van Kooten E Oscar. Plastic solutions for orthopaedic problems.. Archives of orthopaedic and trauma surgery. 2004. DOI: 10.1007/s00402-003-0615-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.