[Double-wire technique for implanting a left ventricular venous lead in patients with complicated coronary venous anatomy].

Arbelo Elena, Medina Alfonso, Bolaños José, García-Quintana Antonio, Caballero Eduardo, Delgado Antonio, Melián Francisco, Amador Celestina, Suárez de Lezo Javier

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

INTRODUCTION AND

OBJECTIVES

Occasionally, implanting a left ventricular pacing electrode for cardiac resynchronization therapy via the coronary sinus may be complicated by the presence of anatomical structures that obstruct the access to the target vein. Our objective was to report on experience using a double-wire technique for implanting left ventricular venous leads gained at the Dr Negrín Hospital in Gran Canaria, Spain.

METHODS

In 20 (12%) of 170 consecutive patients (67 [9] years, 72% male) undergoing implantation of a cardiac resynchronization device, a second parallel hydrophilic guidewire had to be used during lead implantation in the target vein as implantation was impossible without using this technique.

RESULTS

Implantation using a conventional approach was impossible because there was severe tortuosity at the vessel entrance in five patients (25%), a sharp angle at the entrance to the target vein in seven (35%), a venous valve at the vessel entrance in eight (40%), and, finally, poor support for the guiding catheter in four (20%), due to the presence of either a fenestrated Thebesian valve (two patients) or a restrictive Vieussens valve (two patients) that blocked passage of the guiding catheter or electrode. In four patients (20%), there was more than one factor. In all these cases, implantation was achieved in the target vein without complications after passage of a second hydrophilic guidewire.

CONCLUSIONS

The use of a second parallel guidewire (i.e., the double-wire technique) provides a safe and effective way of implanting left ventricular venous pacing electrodes in patients with anatomical complications.

Для цитирования: Arbelo Elena, Medina Alfonso, Bolaños José, García-Quintana Antonio, Caballero Eduardo, Delgado Antonio, Melián Francisco, Amador Celestina, Suárez de Lezo Javier. [Double-wire technique for implanting a left ventricular venous lead in patients with complicated coronary venous anatomy].. Revista espanola de cardiologia. 2007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.