MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/jasms.0c00208

Медицинская библиотека · Journal of the American Society for Mass Spectrometry · 2020

Antigen Retrieval and Its Effect on the MALDI-MSI of Lipids in Formalin-Fixed Paraffin-Embedded Tissue.

Denti Vanna, Piga Isabella, Guarnerio Sonia, Clerici Francesca, Ivanova Mariia, Chinello Clizia, Paglia Giuseppe, Magni Fulvio, Smith Andrew

СтатьяПеревод в очереди

Аннотация

Formalin-fixed paraffin-embedded (FFPE) tissue represents the primary source of clinical tissue and is routinely used in MALDI-MSI studies. However, it is not particularly suitable for lipidomics imaging given that many species are depleted during tissue processing. Irrespective, a number of solvent-resistant lipids remain, but their extraction may be hindered by the cross-link between proteins. Therefore, an antigen retrieval step could enable the extraction of a greater number of lipids and may provide information that is complementary to that which can be obtained from other biomolecules, such as proteins. In this short communication, we aim to address the effect of performing antigen retrieval prior to MALDI-MSI of lipids in FFPE tissue. As a result, an increased number of lipid signals could be detected and may have derived from lipid species that are known to be implicated in the lipid-protein cross-linking that is formed as a result of formalin fixation. Human renal cancer tissue was used as a proof of concept to determine whether using these detected lipid signals were also able to highlight the histopathological regions that were present. These preliminary findings may highlight the potential to enhance the clinical relevance of the lipidomic information obtained from FFPE tissue.

Для цитирования: Denti Vanna, Piga Isabella, Guarnerio Sonia, Clerici Francesca, Ivanova Mariia, Chinello Clizia, Paglia Giuseppe, Magni Fulvio, Smith Andrew. Antigen Retrieval and Its Effect on the MALDI-MSI of Lipids in Formalin-Fixed Paraffin-Embedded Tissue.. Journal of the American Society for Mass Spectrometry. 2020. DOI: 10.1021/jasms.0c00208.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.