MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/rheumatology/ken145

Медицинская библиотека · Rheumatology (Oxford, England) · 2008

Quantification of hardness, elasticity and viscosity of the skin of patients with systemic sclerosis using a novel sensing device (Vesmeter): a proposal for a new outcome measurement procedure.

Kuwahara Y, Shima Y, Shirayama D, Kawai M, Hagihara K, Hirano T, Arimitsu J, Ogata A, Tanaka T, Kawase I

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

No objective method to measure skin involvement in SSc has been established. We developed a novel method using a computer-linked device to simultaneously quantify physical properties of the skin such as hardness, elasticity and viscosity.

METHODS

Skin hardness was calculated by measuring the depth of an indenter pressed onto the skin. The Voigt model was used to calculate skin elasticity, viscosity, visco-elastic ratio and relaxation time by analysing the waveform of skin surface behaviour. The results were compared with the modified Rodnan skin score (mRSS) obtained at 17 sites on the bodies of 20 SSc patients and 20 healthy controls. A functional assessment questionnaire was administered to determine how skin hardness represents a patient's disability. We also examined intra- and inter-observer variability to determine the reliability of this method.

RESULTS

The crude hardness obtained with this device correlated well with the standard hardness specified by the American Society for Testing and Materials (ASTM, r = 0.957). A close relationship between hardness and total mRSS was also observed (r = 0.832). Skin elasticity correlated positively, and relaxation time negatively with mRSS. Functional disability correlated more closely with skin hardness (r = 0.643) than with mRSS (r = 0.517). Intra- and inter-observer variabilities were 7.63 and 19.76%, respectively, which were lower than those reported for mRSS.

CONCLUSIONS

Increases in hardness and elasticity as well as shortening of relaxation time constitute objective characteristics of skin involvement in SSc. The system devised by us proved to be able to assess skin abnormalities of SSc with high reliability.

Для цитирования: Kuwahara Y, Shima Y, Shirayama D, Kawai M, Hagihara K, Hirano T, Arimitsu J, Ogata A, Tanaka T, Kawase I. Quantification of hardness, elasticity and viscosity of the skin of patients with systemic sclerosis using a novel sensing device (Vesmeter): a proposal for a new outcome measurement procedure.. Rheumatology (Oxford, England). 2008. DOI: 10.1093/rheumatology/ken145.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.