MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/opx.0000000000000411

Медицинская библиотека · Optometry and vision science : official publication of the American Academy of Optometry · 2014

Comparison of tear lipid profile among basal, reflex, and flush tear samples.

Rohit Athira, Stapleton Fiona, Brown Simon H J, Mitchell Todd W, Willcox Mark D P

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To determine whether tear collection by flushing the ocular surface with saline (flush tears) or collection by stimulation (reflex tears) can be used as an alternative to basal tear collection for the identification and quantification of lipids in the tear film.

METHODS

Tear samples were collected from 10 participants with no history of ocular surface disease or contact lens wear. Up to 10 μl of basal, reflex, and flush tear samples were collected from each eye using a microcapillary tube on three occasions with the order of methods randomized and allowing at least 24 hours between each collection method. Lipids were quantified from each tear sample using nano-electrospray ionization tandem mass spectrometry.

RESULTS

Total lipids significantly differed in their concentration (pmol/μl) and mole % with each collection technique. Cholesterol esters [mean % (SE)] formed the major component of the total lipidome in basal [54.8% (3.1)], reflex [35.7% (6.4)], and flush [33.0% (3.1)] tear samples. However, the mole % of each lipid class substantially varied with each tear collection method. Nonpolar lipids, including cholesterol, wax esters, and triacylglycerols, dominated the tear lipidome in basal [92.8% (1.9)], reflex [71.8% (7.9)], and flush [83.6% (3.8)] tear samples. However, the mole % of phospholipids in reflex [27.5% (8.1)] and flush [15.8% (3.8)] tear samples was higher (p = 0.005) than that in basal tears [5.4% (2.0)].

CONCLUSIONS

Flush or reflex tears did not have similar lipid profiles in either concentration or in mole % to basal tears. It is recommended that basal tears are used for tear lipid analysis as the reflex or flush tears contain very low levels of most lipid components.

Для цитирования: Rohit Athira, Stapleton Fiona, Brown Simon H J, Mitchell Todd W, Willcox Mark D P. Comparison of tear lipid profile among basal, reflex, and flush tear samples.. Optometry and vision science : official publication of the American Academy of Optometry. 2014. DOI: 10.1097/opx.0000000000000411.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.