[Determination of 21 organophosphate esters and their metabolites in drinking water by automatic solid phase extraction-liquid chromatography-tandem mass spectrometry].
Аннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yuan Rui, Cui Xia, Tong Jing, Ding Wenbo, Fan Sai
Аннотация
OBJECTIVE: To establish a method for simultaneous determination of 21 organophosphate esters(OPEs) and their metabolites in drinking water by automatic solid phase extraction-liquid chromatography-tandem mass spectrometry.
METHODS: The drinking water was purified by automatic solid phase extraction with HLB column, eluted by methanol, determined by liquid chromatography tandem mass spectrometry with ACQUITY UPLC BEH(100 mm×2.1mm, 1.7 μm) column, and quantified by internal standard method.
RESULTS: The optimized method could simultaneously detect 21 organophosphate esters and their metabolites in drinking water. The detection limit was 0.01-0.24 ng/L, the quantitation limit was 0.03-0.77 ng/L. The recovery range was 57.6%-121.2% and the relative standard deviation is 1.2%-11.1% when the concentration was 0.8-20 ng/L. Senventeen tap water and 30 packaged drinking water collected by the supermarket were measured. The ΣOPEs range was 16.8-177 ng/L, and the Σdi-OPEs range was 0.328-16.3ng/L, indicating the exposure risk of organophosphates and their metabolites in water.
CONCLUSION: The pretreatment of the method is simple, automatic and sensitive, and is suitable for simultaneous high-throughput determination of organophosphate esters and their metabolites in large quantities of drinking water.
METHODS: The drinking water was purified by automatic solid phase extraction with HLB column, eluted by methanol, determined by liquid chromatography tandem mass spectrometry with ACQUITY UPLC BEH(100 mm×2.1mm, 1.7 μm) column, and quantified by internal standard method.
RESULTS: The optimized method could simultaneously detect 21 organophosphate esters and their metabolites in drinking water. The detection limit was 0.01-0.24 ng/L, the quantitation limit was 0.03-0.77 ng/L. The recovery range was 57.6%-121.2% and the relative standard deviation is 1.2%-11.1% when the concentration was 0.8-20 ng/L. Senventeen tap water and 30 packaged drinking water collected by the supermarket were measured. The ΣOPEs range was 16.8-177 ng/L, and the Σdi-OPEs range was 0.328-16.3ng/L, indicating the exposure risk of organophosphates and their metabolites in water.
CONCLUSION: The pretreatment of the method is simple, automatic and sensitive, and is suitable for simultaneous high-throughput determination of organophosphate esters and their metabolites in large quantities of drinking water.