Versatile immunosensor using a quantum dot coated silica nanosphere as a label for signal amplification.

Qian Jing, Zhang Chunyan, Cao Xiaodong, Liu Songqin

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A versatile immunosensor using a CdTe quantum dots (QDs) coated silica nanosphere (Si/QD) as a label was proposed for ultrasensitive detection of a biomarker. In this approach, silica nanospheres with good monodispersity and uniform structure were employed as the carrier for immobilization of QDs and antibodies. Rabit IgG served as a model protein to demonstrate the performance of the immunosensor. Goat antirabbit IgG antibody was covalently bound to CdTe QDs on the surface of silica nanospheres. CdTe QDs coated with a silica nanosphere label (Si/QD/Ab2) were attached onto the gold electrode surface through a subsequent "sandwich" immunoreaction. This reaction was confirmed by scanning electron microscopic (SEM) and fluorescence microscopic images. Due to signal amplification from the high loading of CdTe QDs, 6.6- and 5.9-fold enhancements in electrochemiluminescent (ECL) and square-wave voltammetric (SWV) signals for IgG detection were achieved compared to the unamplified method. The detection limits for IgG were 1.3 and 0.6 pg mL(-1) for ECL and SWV measurements, respectively. The resulting versatile immunosensor possesses high sensitivity, satisfactory reproducibility and regeneration, and good precision. This simple and specific strategy has vast potential to be used in other biological assays.

Для цитирования: Qian Jing, Zhang Chunyan, Cao Xiaodong, Liu Songqin. Versatile immunosensor using a quantum dot coated silica nanosphere as a label for signal amplification.. Analytical chemistry. 2010. DOI: 10.1021/ac100558t.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.