MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.14155

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2019

Right ventricular outflow tract low-voltage areas identify the site of origin of idiopathic ventricular arrhythmias: A high-density mapping study.

Letsas Konstantinos P, Efremidis Michael, Vlachos Konstantinos, Asvestas Dimitrios, Takigawa Masateru, Bazoukis George, Frontera Antonio, Giannopoulos George, Saplaouras Athanasios, Sakellaropoulou Antigoni, Mililis Panagiotis, Dragasis Stylianos, Megarisiotou Athanasia, Valkanas Kosmas, Tse Gary, Liu Tong, Deftereos Spyridon, Sideris Antonios, Baranchuk Adrian, Jais Pierre

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Electronatomical mapping allows direct and accurate visualization of myocardial abnormalities. This study investigated whether high-density endocardial bipolar voltage mapping of the right ventricular outflow tract (RVOT) during sinus rhythm may guide catheter ablation of idiopathic ventricular arrhythmias (VAs).

METHODS AND

RESULTS

Forty-four patients (18 males, mean age: 38.1 ± 13.8 years) with idiopathic RVOT VAs and negative cardiac magnetic resonance imaging underwent a stepwise mapping approach for the identification of the site of origin (SOO). High-density electronatomical mapping (1096.6 ± 322.3 points) was performed during sinus rhythm and identified at least two low bipolar voltage areas less than 1 mV (mean amplitude of 0.20 ± 0.10 mV) in 39 of 44 patients. The mean low-voltage surface area was 1.4 ± 0.8 cm2 . Group 1 consisted of 28 patients exhibiting low-voltage areas and high-arrhythmia burden during the procedure. Pace match to the clinical VAs was produced in one of these low-voltage areas. Activation mapping established the SOO at these sites in 27 of 28 cases. Group 2 comprised 11 patients exhibiting abnormal electroanatomical mapping, but very low-arrhythmia burden during the procedure. Pace mapping produced a near-perfect or perfect match to the clinical VAs in one of these areas in 9 of 11 patients which was marked as potential SOO and targeted for ablation. During the follow-up period, 25 of 28 patients from group 1 (89%) and 7 of 9 patients from group 2 (78%) were free from VAs.

CONCLUSIONS

Small but detectable very low-voltage areas during mapping in sinus rhythm characterize the arrhythmogenic substrate of idiopathic RVOT VAs and may guide successful catheter ablation.

Для цитирования: Letsas Konstantinos P, Efremidis Michael, Vlachos Konstantinos, Asvestas Dimitrios, Takigawa Masateru, Bazoukis George, Frontera Antonio, Giannopoulos George, Saplaouras Athanasios, Sakellaropoulou Antigoni, Mililis Panagiotis, Dragasis Stylianos, Megarisiotou Athanasia, Valkanas Kosmas, Tse Gary, Liu Tong, Deftereos Spyridon, Sideris Antonios, Baranchuk Adrian, Jais Pierre. Right ventricular outflow tract low-voltage areas identify the site of origin of idiopathic ventricular arrhythmias: A high-density mapping study.. Journal of cardiovascular electrophysiology. 2019. DOI: 10.1111/jce.14155.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.