m+Medelevator.RU
← Поиск публикаций
ACS biomaterials science & engineering · 2021

Facile Detection of Blood Creatinine Using Binary Copper-Iron Oxide and rGO-Based Nanocomposite on 3D Printed Ag-Electrode under POC Settings.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Singh Preeti, Mandal Soumen, Roy Debolina, Chanda Nripen

Аннотация

Metal nanoparticles have been helpful in creatinine sensing technology under point-of-care (POC) settings because of their excellent electrocatalyst properties. However, the behavior of monometallic nanoparticles as electrochemical creatinine sensors showed limitations concerning the current density in the mA/cm2 range and wide detection window, which are essential parameters for the development of a sensor for POC applications. Herein, we report a new sensor, a reduced graphene oxide stabilized binary copper-iron oxide-based nanocomposite on a 3D printed Ag-electrode (Fe-Cu-rGO@Ag) for detecting a wide range of blood creatinine (0.01 to 1000 μM; detection limit 10 nM) in an electrochemical chip with a current density ranging between 0.185 and 1.371 mA/cm2 and sensitivity limit of 1.1 μA μM-1 cm-2 at physiological pH. Interference studies confirmed that the sensor exhibited no interference from analytes like uric acid, urea, dopamine, and glutathione. The sensor response was also evaluated to detect creatinine in human blood samples with high accuracy in less than a minute. The sensing mechanism suggested that the synergistic effects of Cu and iron oxide nanoparticles played an essential role in the efficient sensing where Fe atoms act as active sites for creatinine oxidation through the secondary amine nitrogen, and Cu nanoparticles acted as an excellent electron-transfer mediator through rGO. The rapid sensor fabrication procedure, mA/cm2 peak current density, a wide range of detection limits, low contact resistance including high selectivity, excellent linear response (R2 = 0.991), and reusability ensured the application of advanced electrochemical sensor toward the POC creatinine detection.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты