MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/rcm.8865

Медицинская библиотека · Rapid communications in mass spectrometry : RCM · 2020

Simple click chemistry-based derivatization to quantify endogenous formaldehyde in milk using ultra-high-performance liquid chromatography/tandem mass spectrometry in selected reaction monitoring mode.

Shetty Sweekruthi A, Rangiah Kannan

СтатьяПеревод в очереди

Аннотация

RATIONALE: Formaldehyde (FA) exposure via environmental pollution or through the food chain poses a serious threat to human health, especially in developing countries like India. Although the addition of FA to food is proscribed, it is often illegally added to foods such as milk to increase the shelf-life. There are challenges in differentiating the endogenous FA content in milk from externally added FA.

METHOD: We have developed a simple method using ultra-high-performance liquid chromatography/tandem mass spectrometry in selected reaction monitoring mode (UHPLC/MS/SRM) for the absolute quantification of endogenous FA in milk. The steps include fat removal, protein precipitation using acid, and spiking with labelled FA (FA*), followed by simple click chemistry-based derivatization using Girard P reagent (GP) and final analysis.

RESULTS

A standard curve with FA* was constructed and used for the calculation of endogenous FA in milk. The optimal conditions for the derivatization reaction using 500 μL of milk were: GP, 50 μg; temperature, 37°C; time, 60 min; and 0.1% HCl. The validation parameters such as accuracy (95.84 to 99.73%), precision (2.84 to 8.02%) and spiked recovery (>95%) are within the FDA guidelines. This method is highly sensitive [limit of detection (LOD) of 1 ng/mL] with a dynamic range of 3.12 to 200 ng/mL. The endogenous FA level in pasteurized cow milk is 70 ng/mL (n = 60). The FA content in raw milk samples from cow, goat and buffalo (each n = 10) varied from 134 to 255 ng/mL.

CONCLUSIONS

This method is precise and sufficiently sensitive to quantify endogenous FA in milk samples using a minimal sample volume. As it involves simple sample preparation steps, it can be used routinely to quantify endogenous FA.

Для цитирования: Shetty Sweekruthi A, Rangiah Kannan. Simple click chemistry-based derivatization to quantify endogenous formaldehyde in milk using ultra-high-performance liquid chromatography/tandem mass spectrometry in selected reaction monitoring mode.. Rapid communications in mass spectrometry : RCM. 2020. DOI: 10.1002/rcm.8865.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.