Spellicy Samantha E, Kilianski Joseph R, Poston Rachel, Moore-Hill Debra, Vale Fernando L
Аннотация
BACKGROUND: Surgical meshes have found widespread use in neurosurgical practice. While commonly recognized risks of synthetic mesh include infection, exposure of mesh implants, and foreign body reaction, the risk of mesh tethering to neural structures is often overlooked.
OBSERVATIONS: The authors presented the first case, to their knowledge, of the disentanglement of mesh interfaced to cortical tissue. The patient, a 68-year-old woman, presented with severe intractable seizure disorder and worsening left hand function and incoordination after meningioma resection and cranioplasty 9 years earlier. Magnetic resonance imaging (MRI) demonstrated interval progression of macrocystic encephalomalacia involving the right supplementary motor area, with fluid-attenuated inversion recovery signal extending posteriorly into the right primary motor cortex. Both computed tomography and MRI suggested potential tethering of the cortex to the overlying cranioplasty mesh. Because of the progressive nature of her condition, the decision was made to surgically remove the tethered mesh.
LESSONS: De-tethering brain parenchyma from surgical mesh requires careful microdissection and judicious use of electrocautery to minimize further tissue damage and preserve neurological function. This inadvertent complication evinces the importance of using dural substitutes when unable to primarily repair the dura to prevent scarring and tethering of neural tissues to synthetic cranioplasty materials.
OBSERVATIONS: The authors presented the first case, to their knowledge, of the disentanglement of mesh interfaced to cortical tissue. The patient, a 68-year-old woman, presented with severe intractable seizure disorder and worsening left hand function and incoordination after meningioma resection and cranioplasty 9 years earlier. Magnetic resonance imaging (MRI) demonstrated interval progression of macrocystic encephalomalacia involving the right supplementary motor area, with fluid-attenuated inversion recovery signal extending posteriorly into the right primary motor cortex. Both computed tomography and MRI suggested potential tethering of the cortex to the overlying cranioplasty mesh. Because of the progressive nature of her condition, the decision was made to surgically remove the tethered mesh.
LESSONS: De-tethering brain parenchyma from surgical mesh requires careful microdissection and judicious use of electrocautery to minimize further tissue damage and preserve neurological function. This inadvertent complication evinces the importance of using dural substitutes when unable to primarily repair the dura to prevent scarring and tethering of neural tissues to synthetic cranioplasty materials.