MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjqs-2015-004284

Медицинская библиотека · BMJ quality & safety · 2015

Guideline-based decision support has a small, non-sustained effect on transthoracic echocardiography ordering frequency.

Boggan Joel C, Schulteis Ryan D, Donahue Mark, Simel David L

СтатьяОбзорПеревод в очереди

Аннотация

BACKGROUND

Guidance for appropriate utilisation of transthoracic echocardiograms (TTEs) can be incorporated into ordering prompts, potentially affecting the number of requests.

METHODS

We incorporated data from the 2011 Appropriate Use Criteria for Echocardiography, the 2010 National Institute for Clinical Excellence Guideline on Chronic Heart Failure, and American College of Cardiology Choosing Wisely list on TTE use for dyspnoea, oedema and valvular disease into electronic ordering systems at Durham Veterans Affairs Medical Center. Our primary outcome was TTE orders per month. Secondary outcomes included rates of outpatient TTE ordering per 100 visits and frequency of brain natriuretic peptide (BNP) ordering prior to TTE. Outcomes were measured for 20 months before and 12 months after the intervention.

RESULTS

The number of TTEs ordered did not decrease (338±32 TTEs/month prior vs 320±33 afterwards, p=0.12). Rates of outpatient TTE ordering decreased minimally post intervention (2.28 per 100 primary care/cardiology visits prior vs 1.99 afterwards, p<0.01). Effects on TTE ordering and ordering rate significantly interacted with time from intervention (p<0.02 for both), as the small initial effects waned after 6 months. The percentage of TTE orders with preceding BNP increased (36.5% prior vs 42.2% after for inpatients, p=0.01; 10.8% prior vs 14.5% after for outpatients, p<0.01).

CONCLUSIONS

Ordering prompts for TTEs initially minimally reduced the number of TTEs ordered and increased BNP measurement at a single institution, but the effect on TTEs ordered was likely insignificant from a utilisation standpoint and decayed over time.

Для цитирования: Boggan Joel C, Schulteis Ryan D, Donahue Mark, Simel David L. Guideline-based decision support has a small, non-sustained effect on transthoracic echocardiography ordering frequency.. BMJ quality & safety. 2015. DOI: 10.1136/bmjqs-2015-004284.