Plasma volume measurement in septic patients using an albumin dilution technique: comparison with the standard radio-labelled albumin method.

Margarson Michael P, Soni Neil C

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To investigate a technique using 20% albumin for measurement of plasma volume in critically ill patients.

DESIGN AND

SETTING

Laboratory and clinical investigation in the adult intensive care unit and anaesthetic laboratories of a university hospital.

PATIENTS: 12 patients fulfilling ACCP/SCCM criteria for septic shock.

INTERVENTIONS AND MEASUREMENTS: Each patient received (125)I-labelled albumin, and the volume of distribution was measured at 1 and 10 min. The accepted standard plasma volume measurement (98% of the 10-min volume of distribution) was calculated. Immediately thereafter 200 ml 20% human albumin was given. Albumin concentrations were measured before and 1 min after this 40-g bolus, and the volume of distribution calculated using a formula that corrected for the 200 ml fluid in which the albumin was dissolved.

RESULTS

Plasma volumes measured using the albumin dilution technique at 1 min were smaller than the standard technique by 110+/-280 ml; limits of agreement were from -660 to +440 ml (-16% to +11%). Plasma volumes measured by (125)I-albumin at 1 min were smaller than the standard by 120+/-110 ml; limits of agreement were from -330 to +100 ml (-8 to +2%).

CONCLUSIONS

Non-labelled albumin can be used easily and quickly to measure a plasma volume in ICU patients and gives a moderately accurate estimate when compared with the (125)I-labelled albumin methods. The normal isotope method over-estimates plasma volumes in septic patients because excessive transcapillary escape of albumin is inadequately compensated for by the standard correction factor.

Для цитирования: Margarson Michael P, Soni Neil C. Plasma volume measurement in septic patients using an albumin dilution technique: comparison with the standard radio-labelled albumin method.. Intensive care medicine. 2004. DOI: 10.1007/s00134-004-2481-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.