MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.28475

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2019

Mid-term outcome in patients with bicuspid aortic valve stenosis following transcatheter aortic valve replacement with a current generation device: A multicenter study.

Attinger-Toller Adrian, Bhindi Rahul, Perlman Gidon Y, Murdoch Dale, Weir-McCall Jonathan, Blanke Philipp, Barbanti Marco, Sathananthan Janarthanan, Ruile Philipp, Gandolfo Caterina, Saia Francesco, Nietlispach Fabian, Wood David, Leipsic Jonathon, Webb John G

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To perform clinical and echocardiographic follow-up beyond 1 year in consecutive patients with severe bicuspid aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with a current generation balloon-expandable valve.

BACKGROUND

Treatment of bicuspid aortic valve disease with TAVR remains controversial and late follow-up data is still scarce.

METHODS

We collected baseline characteristics, procedural data, 30-day and mid-term clinical follow-up findings from six centers in Europe and Canada from patients with bicuspid AS treated with TAVR using the SAPIEN 3 valve.

RESULTS

Seventy-nine patients underwent TAVR. Mean age was 76 ± 9 years; median STS risk score for mortality was 3.8% (interquartile range 2.3-5.5%). Median follow-up was 390 days (interquartile range 138-739 days). Device success was achieved in 95% of patients. Postimplantation mean aortic gradient decreased from 50.2 ± 16.2 to 8.8 ± 4.4 mmHg and no patient had more than mild aortic regurgitation. At last follow-up, there was persistent good valve performance. At 30 days and 1 year, the rates of all-cause mortality were 3.8 and 7.7%, stroke 1.2 and 1.2%, and the rate of new pacemakers 18 and 18%.

CONCLUSIONS

Our data confirm that treating patients with stenotic bicuspid aortic valves is safe, effective, and has favorable valve performance over time.

Для цитирования: Attinger-Toller Adrian, Bhindi Rahul, Perlman Gidon Y, Murdoch Dale, Weir-McCall Jonathan, Blanke Philipp, Barbanti Marco, Sathananthan Janarthanan, Ruile Philipp, Gandolfo Caterina, Saia Francesco, Nietlispach Fabian, Wood David, Leipsic Jonathon, Webb John G. Mid-term outcome in patients with bicuspid aortic valve stenosis following transcatheter aortic valve replacement with a current generation device: A multicenter study.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2019. DOI: 10.1002/ccd.28475.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.