MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2014.06.050

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2014

Functional evaluation of human donation after cardiac death donor hearts using a continuous isolated myocardial perfusion technique: Potential for expansion of the cardiac donor population.

Osaki Satoru, Locher Matthew R, Lushaj Entela B, Akhter Shahab A, Kohmoto Takushi

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To investigate the resuscitation potential and contractile function in adult human donation after cardiac death (DCD) hearts by ex vivo perfusion.

METHODS

With institutional review board approval and under the DCD protocol at the University of Wisconsin (UW) Organ Procurement Organization, 5 brain dead (BD) and 5 DCD donor hearts were evaluated. All BD hearts were declined for clinical transplantation because of coronary artery disease, advanced age, or social history. All hearts were preserved by flushing and cold storage with UW solution. By using our ex vivo perfusion system, the left ventricular end systolic pressure-volume relationship (LV-ESPVR) was assessed for 2 hours of oxygenated blood reperfusion.

RESULTS

All BD (n = 5) and 4 DCD hearts were successfully resuscitated. One DCD heart was unable to be resuscitated due to prolonged warm ischemic time (WIT; 174 minutes). Mean WIT for resuscitated DCD hearts (from extubation to flushing with cold UW solution) was 34 ± 3 minutes (range, 26 to 40 minutes); mean cold ischemic time for BD donors was 211 ± 31 minutes compared with 177 ± 64 minutes for DCD donors. The calculated LV-ESPVRs for BD hearts after 1 and 2 hours of reperfusion were 6.9 ± 0.7 and 5.7 ± 1.0 mm Hg/mL, respectively; LV-ESPVRs for DCD hearts after 1 and 2 hours of reperfusion were 5.6 ± 1.5 (P = .45) and 3.0 ± 0.7 mm Hg/mL (P = .07), respectively.

CONCLUSIONS

We successfully resuscitated and measured ex vivo cardiac function in human DCD and BD donor hearts. Resuscitation potential in DCD hearts was achieved when the WIT was less than 40 minutes. Contractile performance in DCD hearts tended to be lower compared with BD hearts. Further investigation with longer reperfusion periods seems warranted.

Для цитирования: Osaki Satoru, Locher Matthew R, Lushaj Entela B, Akhter Shahab A, Kohmoto Takushi. Functional evaluation of human donation after cardiac death donor hearts using a continuous isolated myocardial perfusion technique: Potential for expansion of the cardiac donor population.. The Journal of thoracic and cardiovascular surgery. 2014. DOI: 10.1016/j.jtcvs.2014.06.050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.