m+Medelevator.RU
← Поиск публикаций
International journal of radiation oncology, biology, physics · 2025

Multidisciplinary Consensus Prostate Contours on Magnetic Resonance Imaging: Educational Atlas and Reference Standard for Artificial Intelligence Benchmarking.

СтатьяConsensus StatementПоддержка NIH: внешняя программаНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Song Yuze, Dornisch Anna M, Dess Robert T, Margolis Daniel J A, Weinberg Eric P, Barrett Tristan, Cornell Mariel, Fan Richard E, Harisinghani Mukesh, Kamran Sophia C, Lee Jeong Hoon, Li Cynthia Xinran, Liss Michael A, Rusu Mirabela, Santos Jason, Sonn Geoffrey A, Vidic Igor, Woolen Sean A, Dale Anders M, Seibert Tyler M

Аннотация

PURPOSE: Evaluation of artificial intelligence (AI) algorithms for prostate segmentation is challenging because ground truth is lacking. We aimed to: (1) create a reference standard data set with precise prostate contours by expert consensus, and (2) evaluate various AI tools against this standard.

METHODS AND MATERIALS: We obtained prostate magnetic resonance imaging cases from six institutions from the Qualitative Prostate Imaging Consortium. A panel of 4 experts (2 genitourinary radiologists and 2 prostate radiation oncologists) meticulously developed consensus prostate segmentations on axial T2-weighted series. We evaluated the performance of 6 AI tools (3 commercially available and 3 academic) using Dice scores, distance from reference contour, and volume error.

RESULTS: The panel achieved consensus prostate segmentation on each slice of all 68 patient cases included in the reference data set. We present 2 patient examples to serve as contouring guides. Depending on the AI tool, median Dice scores (across patients) ranged from 0.80 to 0.94 for whole prostate segmentation. For a typical (median) patient, AI tools had a mean error over the prostate surface ranging from 1.3 to 2.4 mm. They maximally deviated 3.0 to 9.4 mm outside the prostate and 3.0 to 8.5 mm inside the prostate for a typical patient. Error in prostate volume measurement for a typical patient ranged from 4.3% to 31.4%.

CONCLUSIONS: We established an expert consensus benchmark for prostate segmentation. The best-performing AI tools have typical accuracy greater than that reported for radiation oncologists using computed tomography scans (the most common clinical approach for radiation therapy planning). Physician review remains essential to detect occasional major errors.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты