MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-020-58902-x

Медицинская библиотека · Scientific reports · 2020

Inhaled milrinone in cardiac surgical patients: a pilot randomized controlled trial of jet vs. mesh nebulization.

Nguyen Anne Quynh-Nhu, Denault André Y, Théoret Yves, Perrault Louis P, Varin France

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Inhaled milrinone administered before cardiopulmonary bypass (CPB) reduces the severity of pulmonary hypertension during cardiac surgery. However, milrinone pharmacokinetics has not been determined for this route of administration. The objective of this study was to investigate inhaled milrinone dosing in vitro and early plasma concentrations in vivo after jet and mesh nebulization. Twelve pulmonary hypertensive patients scheduled for cardiac surgery were randomized to receive milrinone (5 mg) by inhalation before CPB using a jet or mesh nebulizer. In vitro experiments were conducted to determine the inhaled dose delivered with either jet or mesh nebulization. In vivo experiments involved hemodynamic monitoring and blood samples drawn from patients for the first 15 min after the end of inhalation to determine early plasma concentrations. After mesh nebulization, the mean in vitro inhaled dose was almost 3-fold higher compared to jet nebulization (46.4% vs 16.6% for mesh and jet, respectively; mean difference, 29.8%; 95% CI, 14.1 to 45.5; P = 0.006). Consistent with this, the early plasma concentrations in vivo were also 2-3 fold higher after mesh nebulization (P = 0.002-0.005). After inhalation (jet or mesh nebulization), milrinone early plasma concentrations remained within the therapeutic range. No systemic hypotension was reported in our patients.

Для цитирования: Nguyen Anne Quynh-Nhu, Denault André Y, Théoret Yves, Perrault Louis P, Varin France. Inhaled milrinone in cardiac surgical patients: a pilot randomized controlled trial of jet vs. mesh nebulization.. Scientific reports. 2020. DOI: 10.1038/s41598-020-58902-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.