Acute respiratory distress associated with external jugular vein catheterization in the newborn.

Bitar Fadi F, Obeid Mounir, Dabbous Ibrahim, Hayek Paula, Akel Samir, Mroueh Salman

Клинический случайСтатьяПеревод в очереди

Аннотация

We report on the acute onset of respiratory distress secondary to fluid accumulation in the chest within hours of placement of an external jugular venous line in a newborn. External jugular venous catheterization in the newborn is a procedure with potentially serious complications, and should be avoided unless the patient is monitored closely.