MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/polym12050998

Медицинская библиотека · Polymers · 2020

Colorimetric Visualization Using Polymeric Core-Shell Nanoparticles: Enhanced Sensitivity for Formaldehyde Gas Sensors.

Park Jae Jung, Kim Yongsoo, Lee Chanmin, Kook Jun-Won, Kim Donghyun, Kim Jung-Hyun, Hwang Ki-Seob, Lee Jun-Young

СтатьяПеревод в очереди

Аннотация

Although equipment-based gas sensor systems (e.g., high-performance liquid chromatography) have been widely applied for formaldehyde gas detection, pre-treatment and expensive instrumentation are required. To overcome these disadvantages, we developed a colorimetric sensor based on polymer-based core-shell nanoparticles (PCSNPs), which are inexpensive, stable, and exhibit enhanced selectivity. Spherical and uniform poly(styrene-co-maleic anhydride) (PSMA)/polyethyleneimine (PEI) core-shell nanoparticles were prepared and then impregnated with Methyl Red (MR), Bromocresol Purple (BCP), or 4-nitrophenol (4-NP) to construct colorimetric sensors for formaldehyde gas. The intrinsic properties of these dyes were maintained when introduced into the PCSNPs. In the presence of formaldehyde, the MR, BCP, and 4-NP colorimetric sensors changed to yellow, red, and gray, respectively. The colorimetric response was maximized at a PEI/PSMA ratio of four, likely owing to the high content of amine groups. Effective formaldehyde gas detection was achieved at a relative humidity of 30% using the MR colorimetric sensor, which exhibited a large color change (92%) in 1 min. Advantageously, this stable sensor allowed sensitive and rapid naked-eye detection of low formaldehyde concentrations (0.5 ppm). Hence, this approach is promising for real-time formaldehyde gas visualization and can also be adapted to other colorimetric gas sensor systems to improve sensitivity and simplicity.

Для цитирования: Park Jae Jung, Kim Yongsoo, Lee Chanmin, Kook Jun-Won, Kim Donghyun, Kim Jung-Hyun, Hwang Ki-Seob, Lee Jun-Young. Colorimetric Visualization Using Polymeric Core-Shell Nanoparticles: Enhanced Sensitivity for Formaldehyde Gas Sensors.. Polymers. 2020. DOI: 10.3390/polym12050998.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.