Cardiovascular toxicology · 2024
Association of Metal Cations with the Anti-PF4/Heparin Antibody Response in Heparin-Induced Thrombocytopenia.
СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Giles Jason B, Martinez Kiana L, Steiner Heidi E, Klein Andrew, Ooi Aikseng, Pryor Julie, Sweitzer Nancy, Fuchs Deborah, Karnes Jason H
Аннотация
Heparin-induced thrombocytopenia (HIT) is an antibody-mediated immune response against complexes of heparin and platelet factor 4 (PF4). The electrostatic interaction between heparin and PF4 is critical for the anti-PF4/heparin antibody response seen in HIT. The binding of metal cations to heparin induces conformational changes and charge neutralization of the heparin molecule, and cation-heparin binding can modulate the specificity and affinity for heparin-binding partners. However, the effects of metal cation binding to heparin in the context of anti-PF4/heparin antibody response have not been determined. Here, we utilized inductively coupled plasma mass spectrometry (ICP-MS) to quantify 16 metal cations in patient plasma and tested for correlation with anti-PF4/heparin IgG levels and platelet count after clinical suspicion of HIT in a cohort of heparin-treated patients. The average age of the cohort (n = 32) was 60.53 (SD = 14.31) years old, had a mean anti-PF4/heparin antibody optical density [OD405] of 0.93 (SD = 1.21) units, and was primarily female (n = 23). Patients with positive anti-PF4/heparin antibody test results (OD405 ≥ 0.5 units) were younger, had increased weight and BMI, and were more likely to have a positive serotonin release assay (SRA) result compared to antibody-negative patients. We observed statistical differences between antibody-positive and -negative groups for sodium and aluminum and significant correlations of anti-PF4/heparin antibody levels with sodium and silver. While differences in sodium concentrations were associated with antibody-positive status and correlated with antibody levels, no replication was performed. Additional studies are warranted to confirm our observed association, including in vitro binding studies and larger observational cohorts.