MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2020.01.017

Медицинская библиотека · Heart rhythm · 2020

Prevalence and clinical impact of spontaneous and adenosine-induced pulmonary vein reconduction in the Contact-Force vs. Cryoballoon Atrial Fibrillation Ablation (CIRCA-DOSE) study.

Andrade Jason G, Deyell Marc W, Nattel Stanley, Khairy Paul, Dubuc Marc, Champagne Jean, Leong-Sit Peter, Jolly Umjeet, Badra-Verdu Mariano, Sapp John, Verma Atul, Macle Laurent, CIRCA-DOSE Study Investigators

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Use of intraprocedural observation and pharmacologic challenges have been proposed as means to differentiate permanent pulmonary vein (PV)-left atrial conduction block from inadequate ablation lesions.

OBJECTIVE

The purpose of this study was to determine the prevalence and clinical impact of spontaneous and adenosine-provoked reconnection using contemporary atrial fibrillation (AF) ablation technologies.

METHODS

The CIRCA-DOSE (Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation: Double Short vs. Standard Exposure Duration) study enrolled 346 patients with paroxysmal AF and randomized them to contact force-guided radiofrequency ablation (CF-RF) or cryoballoon ablation. Patients underwent provocative testing with adenosine after a 20-minute observation period. All patients received an implantable cardiac monitor for arrhythmia monitoring.

RESULTS

Spontaneous reconnection was observed in 5.4% of PVs (71/1318) during the 20-minute postprocedure observation period, and dormant conduction was elicited in 5.7% of PVs (75/1318). Both spontaneous reconnection and dormant conduction were more common after CF-RF compared to cryoballoon ablation (P = .03 and P <.0001, respectively). Acute PV reconnection (spontaneous or adenosine-provoked) was associated with a significantly higher incidence of recurrent atrial tachyarrhythmia in the cryoballoon group (hazard ratio [HR] 2.39; 95% confidence interval [CI] 1.44-3.96; P = .0007) but not in the CF-RF group (HR 1.47; 95% CI 0.84-2.58; P = .16). In the absence of acute reconnection, the freedom from recurrent arrhythmia did not differ between groups (HR 0.95; 95% CI 0.6057-1.495; P = .83).

CONCLUSION

Patients without spontaneous or adenosine-provoked reconnection had better outcomes compared to those with acute PV reconnection, suggesting that efforts should be directed toward ensuring an ideal ablation lesion at the first attempt in order to achieve durable PV isolation.

Для цитирования: Andrade Jason G, Deyell Marc W, Nattel Stanley, Khairy Paul, Dubuc Marc, Champagne Jean, Leong-Sit Peter, Jolly Umjeet, Badra-Verdu Mariano, Sapp John, Verma Atul, Macle Laurent, CIRCA-DOSE Study Investigators. Prevalence and clinical impact of spontaneous and adenosine-induced pulmonary vein reconduction in the Contact-Force vs. Cryoballoon Atrial Fibrillation Ablation (CIRCA-DOSE) study.. Heart rhythm. 2020. DOI: 10.1016/j.hrthm.2020.01.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.