MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jviromet.2013.08.039

Медицинская библиотека · Journal of virological methods · 2013

Development of a Usutu virus specific real-time reverse transcription PCR assay based on sequenced strains from Africa and Europe.

Nikolay B, Weidmann M, Dupressoir A, Faye O, Boye C S, Diallo M, Sall A A

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

Usutu virus (USUV) has been isolated in several African and European countries mainly from mosquitoes and birds. However, previous benign and two recent severe cases of human infections point out the need of a tool for the identification of USUV in human samples. A published real-time reverse transcription (RT) PCR assay for the detection of USUV in human blood or cerebrospinal fluid does not take into account the genetic variability of USUV in different geographic regions. Therefore, this article presents a quantitative real-time RT-PCR assay based on sequences from Europe and Africa. Primers and probe were designed in conserved regions among USUV strains that differed from closely related flaviviruses. The specificity of the assay was investigated by testing 16 other flaviviruses circulating in Africa. The sensitivity was determined by testing serial dilutions of virus and RNA standard. Intra- and inter-assay coefficients of variation were evaluated by 10 reactions in a same and in different assays, respectively. The assay provides high analytical specificity for USUV and detection limits of 1.2pfu/reaction for virus dilutions in L-15 medium or human serum and 60 copies/reaction for the RNA standard. The assay needs to be evaluated in a clinical context and integrated in standard diagnosis of flaviviral diseases.

Для цитирования: Nikolay B, Weidmann M, Dupressoir A, Faye O, Boye C S, Diallo M, Sall A A. Development of a Usutu virus specific real-time reverse transcription PCR assay based on sequenced strains from Africa and Europe.. Journal of virological methods. 2013. DOI: 10.1016/j.jviromet.2013.08.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.