MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.12840

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2016

Pain Reactions during Pulmonary Vein Isolation under Deep Sedation: Cryothermal versus Radiofrequency Ablation.

Attanasio Philipp, Huemer Martin, Shokor Parwani Abdul, Boldt Leif-Hendrik, Mügge Andreas, Haverkamp Wilhelm, Wutzler Alexander

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Left atrial ablation can be accompanied by discomfort or pain. The purpose of this study was to systematically compare pain reactions during ablation of atrial fibrillation under deep sedation with cryothermal and radiofrequency energy.

METHODS AND

RESULTS

Circumferential ablation was performed in patients with atrial fibrillation using either radiofrequency (RF) or cryoenergy. Deep sedation was achieved with a combination of propofol and midazolam. Pain reactions were counted and painful ablation sites located. To determine the severity of the pain reactions a Face, Legs, Activity, Cry, Consolability (FLACC) Behavioral Pain Assessment Scale was used: 79 patients (53 RF- vs 26 Cryoablations) were included. A total of 92% of patients treated with RF energy showed ≥1 pain reaction during the procedure compared to only 13% in the cryoenergy group (<0.001). The total number of pain reactions was significantly higher in the RF energy group (3.6 ± 4.7 vs1.3 ± 0.6, P = 0.005). Determination of painful sites was performed in the RF group only. Pain reactions were significantly more often observed during RF application left superior pulmonary vein (LSPV) ostium compared to other left atrial ablation sites (Total FLACC Score 2.8 ± 0.6 LSPV, 1.4 ± 0.4 left inferior pulmonary vein [P = 0.009], 1.4 ± 0.3 right superior pulmonary vein [P = 0.044], 1.1 ± 0.3 right inferior pulmonary vein [P = 0.032]).

CONCLUSIONS

Our results show that despite deep sedation pain reactions often occur during RF ablation. Knowledge of areas with more frequent pain reactions may help electrophysiologists to reduce pain reactions and related patient movements. Ablation with cryoenergy was significantly less painful compared to ablation with RF energy. Cryoablation therefore may be considered for patients at a higher risk for anesthesia-related complications.

Для цитирования: Attanasio Philipp, Huemer Martin, Shokor Parwani Abdul, Boldt Leif-Hendrik, Mügge Andreas, Haverkamp Wilhelm, Wutzler Alexander. Pain Reactions during Pulmonary Vein Isolation under Deep Sedation: Cryothermal versus Radiofrequency Ablation.. Pacing and clinical electrophysiology : PACE. 2016. DOI: 10.1111/pace.12840.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.