DOI 10.1056/nejm199110103251501
Abnormal coronary vasoconstriction as a predictor of restenosis after successful coronary angioplasty in patients with unstable angina pectoris.
Аннотация
BACKGROUND
High rates of restenosis after coronary angioplasty have been reported in patients with vasospastic angina. This study was designed to determine whether the occurrence of abnormal coronary vasoconstriction, detected by means of hyperventilation testing before angioplasty, influences the risk of restenosis after successful dilation.
METHODS
Hyperventilation testing was performed 0 to 4 days before coronary angioplasty in 106 consecutive patients with unstable angina and single-vessel coronary artery disease. Abnormal coronary vasoconstriction was considered present if hyperventilation-induced myocardial ischemia occurred during the recovery phase of the test. All patients had follow-up angiography 8 to 12 months after angioplasty.
RESULTS
Abnormal coronary vasoconstriction was observed in 48 patients (group 1), whereas 58 patients (group 2) had either a negative response throughout the test or a positive response only during the overbreathing phase of the hyperventilation test. Angioplasty was successful in 40 patients in group 1 and 51 in group 2. Restenosis was documented in 29 patients (73 percent) in group 1 and 13 (25 percent) in group 2 (relative risk of restenosis, 2.84; 95 percent confidence interval, 1.69 to 4.28; P less than 0.001). In a multivariate analysis, the following three characteristics were independently related to the risk of restenosis (in descending order of importance): ST-segment elevation during spontaneous ischemic attacks (P less than 0.001), hyperventilation-induced abnormal coronary vasoconstriction (P less than 0.001), and the presence of a lesion more than 10 mm long in the left anterior descending coronary artery (P less than 0.05).
CONCLUSIONS
In patients with unstable angina and single-vessel coronary artery disease who have been selected for coronary angioplasty, the presence of hyperventilation-induced abnormal coronary vasoconstriction identifies a subgroup at high risk for restenosis.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.