MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/molecules30030646

Медицинская библиотека · Molecules (Basel, Switzerland) · 2025

An Environmental Engineering Study Case: Constructing Cataluminescence Sensors Based on Octahedral Nanocomposites for Isovaleraldehyde Detection.

Sun Bai, Cai Mao, Shi Guoji, Wang Yun, Bao Lining, Zhao Qiang, Yi Mingjian, Zhu Shuguang

СтатьяПеревод в очереди

Аннотация

Isovaleraldehyde is an important chemical raw material for the production of flavors, which is volatile and flammable and poses a health risk to humans. It is, therefore, essential to develop a rapid assay for the identification of isovaleraldehyde. In this study, octahedral NiCo2O4/MIL-Fe53 nanocomposites were successfully fabricated for the rapid detection of isovaleraldehyde. The prepared NiCo2O4/MIL-Fe53 nanocomposites were characterized by SEM, XRD, FTIR, and XPS to analyze the material properties. The effects of temperature, carrier gas flow rate, selectivity, and stability on the cataluminescence performance of this sensor were investigated. The results showed that NiCo2O4/MIL-Fe53 nanocomposites have excellent selectivity to isovaleraldehyde with response and recovery times of 6 and 8 s, respectively. A linear relationship was found between the CTL signal and isovaleraldehyde concentration Y = 9.56X - 23.3 (R2 = 0.99) over the concentration range of 13.66 to 437.22 ppm with a detection limit of 2.44 ppm. The relative deviation RSD = 4.18% for multiple tests of the sensor indicates good stability and longevity. Mechanistic studies have shown that the heterojunction formed by NiCo2O4/MIL-Fe53 nanocomposites has the advantage of improving CTL sensing performance. This study may advance the application of cataluminescence sensors in the detection of isovaleraldehyde.

Для цитирования: Sun Bai, Cai Mao, Shi Guoji, Wang Yun, Bao Lining, Zhao Qiang, Yi Mingjian, Zhu Shuguang. An Environmental Engineering Study Case: Constructing Cataluminescence Sensors Based on Octahedral Nanocomposites for Isovaleraldehyde Detection.. Molecules (Basel, Switzerland). 2025. DOI: 10.3390/molecules30030646.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.