MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm10102158

Медицинская библиотека · Journal of clinical medicine · 2021

Evaluation of Anti-Activated Factor X Activity and Activated Partial Thromboplastin Time Relations and Their Association with Bleeding and Thrombosis during Veno-Arterial ECMO Support: A Retrospective Study.

Moussa Mouhamed Djahoum, Soquet Jérôme, Lamer Antoine, Labreuche Julien, Gantois Guillaume, Dupont Annabelle, Abou-Arab Osama, Rousse Natacha, Liu Vincent, Brandt Caroline, Foulon Valentin, Leroy Guillaume, Schurtz Guillaume, Jeanpierre Emmanuel, Duhamel Alain, Susen Sophie, Vincentelli André, Robin Emmanuel

СтатьяПеревод в очереди

Аннотация

BACKGROUND

We aimed to investigate the relationship between anti-activated Factor X (anti-FXa) and activated Partial Thromboplastin Time (aPTT), and its modulation by other haemostasis co-variables during veno-arterial extracorporeal membrane oxygenation (VA-ECMO) support. We further investigated their association with serious bleeding and thrombotic complications.

METHODS

This retrospective single-center study included 265 adults supported by VA-ECMO for refractory cardiogenic shock from January 2015 to June 2019. The concordance of anti-FXa and aPTT and their correlations were assessed in 1699 paired samples. Their independent associations with serious bleeding or thrombotic complications were also analysed in multivariate analysis.

RESULTS

The concordance rate of aPTT with anti-FXa values was 50.7%, with 39.3% subtherapeutic aPTT values. However, anti-FXa and aPTT remained associated (β = 0.43 (95% CI 0.4-0.45) 10-2 IU/mL, p < 0.001), with a significant modulation by several biological co-variables. There was no association between anti-FXa nor aPTT values with serious bleeding or with thrombotic complications.

CONCLUSION

During VA-ECMO, although anti-FXa and aPTT were significantly associated, their values were highly discordant with marked sub-therapeutic aPTT values. These results should favour the use of anti-FXa. The effect of biological co-variables and the failure of anti-FXa and aPTT to predict bleeding and thrombotic complications underline the complexity of VA-ECMO-related coagulopathy.

Для цитирования: Moussa Mouhamed Djahoum, Soquet Jérôme, Lamer Antoine, Labreuche Julien, Gantois Guillaume, Dupont Annabelle, Abou-Arab Osama, Rousse Natacha, Liu Vincent, Brandt Caroline, Foulon Valentin, Leroy Guillaume, Schurtz Guillaume, Jeanpierre Emmanuel, Duhamel Alain, Susen Sophie, Vincentelli André, Robin Emmanuel. Evaluation of Anti-Activated Factor X Activity and Activated Partial Thromboplastin Time Relations and Their Association with Bleeding and Thrombosis during Veno-Arterial ECMO Support: A Retrospective Study.. Journal of clinical medicine. 2021. DOI: 10.3390/jcm10102158.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.