MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/08035250310002597

Медицинская библиотека · Acta paediatrica (Oslo, Norway : 1992) · 2003

Prediction of respiratory distress syndrome by the microbubble stability test on gastric aspirates in newborns of less than 32 weeks' gestation.

Verder H, Ebbesen F, Linderholm B, Robertson B, Eschen C, Arrøe M, Lange A, Grytter C, Bohlin K, Bertelsen A, Danish-Swedish Multicentre Study Group

СтатьяПеревод в очереди

Аннотация

AIM: There is a need for a rapid method to identify infants who will develop respiratory distress syndrome (RDS) soon after birth, to allow early treatment of affected infants with surfactant. The microbubble stability test (MST) may be one such method, but clinical experience is sparse.

METHODS

The MST was performed on gastric aspirates from 188 infants with a mean gestational age of 29 (range 23-31) wk.

RESULTS

87 infants developed moderate to severe RDS, corresponding to a prevalence of 46%. The sensitivity, specificity and predictive values for identification of infants with moderate to severe RDS were determined for the average diameter of bubbles, the proportion of microbubbles with different diameters and the total number of microbubbles. The proportion of microbubbles with diameters <20 or 25 microm gave the best prediction, with a sensitivity of 78-79%, a specificity of 57-58%, a positive predictive value of 62% and a negative predictive value of 76%. Early treatment with nasal continuous positive airway pressure probably mitigated the development of RDS in some infants with a low-degree surfactant deficiency and this may explain the relatively low specificity.

CONCLUSION

In infants of <32 wk gestation RDS can be predicted by computerized image analysis of the size distribution of microbubbles generated in gastric aspirates.

Для цитирования: Verder H, Ebbesen F, Linderholm B, Robertson B, Eschen C, Arrøe M, Lange A, Grytter C, Bohlin K, Bertelsen A, Danish-Swedish Multicentre Study Group. Prediction of respiratory distress syndrome by the microbubble stability test on gastric aspirates in newborns of less than 32 weeks' gestation.. Acta paediatrica (Oslo, Norway : 1992). 2003. DOI: 10.1080/08035250310002597.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.