Helicobacter pylori Breath Test via Mid-Infrared Sensor Technology.

Flores Rangel Gabriela, Diaz de León Martinez Lorena, Mizaikoff Boris

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Helicobacter pylori infection has been associated with various gastrointestinal disorders, most notably with the development of gastric cancer. Therefore, it is important to develop technologies for effective, rapid, sensitive, and personalized infection detection. The present study evaluates the utility of mid-infrared (MIR) exhaled breath sensors utilizing substrate-integrated hollow waveguide (iHWG) technology for the precise determination of the isotopic ratio of 13CO2 vs 12CO2 simulating conditions relevant to the detection of the presence of Helicobacter pylori in the upper gastrointestinal tract via exhaled breath analysis. For future integration of such a sensing module, e.g., into a cell phone attachment, optimized light-gas interaction and sufficient sensitivity are essential, as the diagnosis is based on detecting the presence of 13CO2 30 min after administration of 13C-labeled urea via a gel or pill, which is metabolized by H. pylori. By optimizing the light-gas interaction volume via tailoring of the iHWG, it was demonstrated that sufficient sensitivity and accuracy are achieved for detecting small changes in the isotopic composition of exhaled CO2. While it was demonstrated that the combination of conventional Fourier-transform infrared (FTIR) spectroscopy with iHWGs indeed confirms the utility of this noninvasive breath analysis concept, further device miniaturization utilizing quantum cascade lasers is anticipated to achieve the necessary level of integration for personalized home usage.

Для цитирования: Flores Rangel Gabriela, Diaz de León Martinez Lorena, Mizaikoff Boris. Helicobacter pylori Breath Test via Mid-Infrared Sensor Technology.. ACS sensors. 2025. DOI: 10.1021/acssensors.4c02785.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.