m+Medelevator.RU
← Поиск публикаций
Journal of cardiac failure · 2021

Aortic Pulsatility Index: A Novel Hemodynamic Variable for Evaluation of Decompensated Heart Failure.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Belkin Mark N, Kalantari Sara, Kanelidis Anthony J, Miller Tamari, Smith Bryan A, Besser Stephanie A, Tehrani David, Chung Ben B, Nguyen Ann, Sarswat Nitasha, Blair John E A, Burkhoff Daniel, Sayer Gabriel, Pinney Sean P, Uriel Nir, Kim Gene, Grinstein Jonathan

Аннотация

BACKGROUND: Right heart catheterization for invasive hemodynamics has shown only modest correlation with clinical outcomes. We designed a novel hemodynamic variable that incorporates ventricular output and filling pressure. We anticipated that the aortic pulsatility index (API) would correlate with clinical outcomes in patients with heart failure.

METHODS AND RESULTS: We retrospectively analyzed consecutive patients undergoing right heart catheterization with milrinone drug study at our institution (February 2013 to November 2019). The API was calculated as (systolic blood pressure - diastolic blood pressure)/pulmonary capillary wedge pressure. The primary outcome was freedom from advanced therapies, defined as the need for inotropes, temporary mechanical circulatory support, a left ventricular assist device, or orthotopic heart transplantation, or death at 30 days. A total of 224 patient encounters, age 57 years (48-66 years; 34% women; 31% ischemic cardiomyopathy) were included. In univariable analysis, lower baseline API was significantly associated with progression to advanced therapies or death at 30-days (odds ratio 0.43, 95% confidence interval 0.30-0.61; P < .001) compared with those on continued medical management. Receiver operator characteristic analysis specified an optimal cutpoint of 1.45 for API. A Kaplan-Meier analysis indicated an association of API with the primary outcome (79% for API ≥ 1.45 vs 48% for API < 1.45). In multivariable analysis, higher API was strongly associated with freedom from advanced therapies or death (odds ratio 0.38, 95% confidence interval 0.22-0.65, P ≤ .001), even when adjusted for baseline characteristics and routine right heart catheterization measurements.

CONCLUSIONS: The API is a novel invasive hemodynamic measurement that is associated independently with freedom from advanced therapies or death at 30-day follow-up.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты