MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2019.07.018

Медицинская библиотека · Heart rhythm · 2019

Right anterior ganglionated plexus: The primary target of cardioneuroablation?

Hu Feng, Zheng Lihui, Liang Erpeng, Ding Ligang, Wu Lingmin, Chen Gang, Fan Xiaohan, Yao Yan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Catheter ablation of ganglionated plexus (GP) as cardioneuroablation in the left atrium (LA) has been used to treat vasovagal syncope (VVS).

OBJECTIVE

The purpose of this study was to assess the effects of ablation of GPs on heart rate and to observe the acute, short-term, and long-term effects after cardioneuroablation.

METHODS

A total of 115 consecutive patients with VVS who underwent cardioneuroablation were enrolled. GPs of the LA were identified by high-frequency stimulation and/or anatomic landmarks being targeted by radiofrequency catheter ablation.

RESULTS

During ablation of right anterior ganglionated plexus (RAGP), heart rate increased from 61.3 ± 12.2 bpm to 82.4 ± 14.7 bpm (P <.001), whereas during ablation of other GPs only vagal responses were observed. During follow-up of 21.4 ± 13.1 months (median 18 months), 106 participants (92.2%) had no recurrence of syncope or presyncope. Holter data showed that minimal heart rate significantly increased at all follow-up time points (all P<.05), and mean heart rate remained higher than baseline 12 months after ablation (P = .001).

CONCLUSION

Cardioneuroablation via GP ablation in the LA effectively inhibited the recurrence of VVS. Ablation of RAGP could increase heart rate immediately and for the long term. This unique phenomenon may provide a new potential approach for treatment of neural reflex syncope or bradyarrhythmias.

Для цитирования: Hu Feng, Zheng Lihui, Liang Erpeng, Ding Ligang, Wu Lingmin, Chen Gang, Fan Xiaohan, Yao Yan. Right anterior ganglionated plexus: The primary target of cardioneuroablation?. Heart rhythm. 2019. DOI: 10.1016/j.hrthm.2019.07.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.