Ozone exposure in humans: inflammatory, small and peripheral airway responses.

Weinmann G G, Liu M C, Proud D, Weidenbach-Gerbase M, Hubbard W, Frank R

СтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

We exposed eight normal adults to filtered air (FA) and 0.35 ppm ozone (O3) and compared responses in spirometry, including isovolume (isoV) flows at intermediate-to-low lung volumes, against levels of inflammatory markers in bronchoalveolar lavage fluid (BALF) and peripheral lung resistance (Rp) measured through a wedged bronchoscope. Spirometry was performed at the end, 25 min and 24 h after exposure, bronchoscopy at 24 h after exposure. The percentages of neutrophils, fibrinogen, albumin, PGE2, PGF2 alpha, and kinins were elevated in BALF after O3 compared with FA. The percentage reduction in (isoV) FEF25-75 at 25 min and 24 h after administration of O3 correlated closely with the rise in fibrinogen concentrations in BALF, a marker of altered vascular permeability. Rp, a measurement dominated by very small or peripheral airways, was unaffected in 7 of 8 subjects. The absence of change in Rp might have reflected insufficient penetration of O3 into these airways to produce or sustain an effect for 24 h; alternatively, the bronchoscopic procedure which included atropine and lidocaine pretreatment may have reversed an O3 effect. An unexpected finding was the significant association between baseline Rp (after FA) and the magnitude of the spirometric response to O3. Our results suggest that small airway dysfunction in the immediate post-O3 period is a marker of lung inflammation.

Для цитирования: Weinmann G G, Liu M C, Proud D, Weidenbach-Gerbase M, Hubbard W, Frank R. Ozone exposure in humans: inflammatory, small and peripheral airway responses.. American journal of respiratory and critical care medicine. 1995. DOI: 10.1164/ajrccm.152.4.7551367.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.