MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5812/aapm.31111

Медицинская библиотека · Anesthesiology and pain medicine · 2015

Ultrasound-Guided Out-of-Plane vs. In-Plane Interscalene Catheters: A Randomized, Prospective Study.

Schwenk Eric S, Gandhi Kishor, Baratta Jaime L, Torjman Marc, Epstein Richard H, Chung Jaeyoon, Vaghari Benjamin A, Beausang David, Bojaxhi Elird, Grady Bernadette

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Continuous interscalene blocks provide excellent analgesia after shoulder surgery. Although the safety of the ultrasound-guided in-plane approach has been touted, technical and patient factors can limit this approach. We developed a caudad-to-cephalad out-of-plane approach and hypothesized that it would decrease pain ratings due to better catheter alignment with the brachial plexus compared to the in-plane technique in a randomized, controlled study.

OBJECTIVES

To compare an out-of-plane interscalene catheter technique to the in-plane technique in a randomized clinical trial.

PATIENTS AND

METHODS

Eighty-four patients undergoing open shoulder surgery were randomized to either the in-plane or out-of-plane ultrasound-guided continuous interscalene technique. The primary outcome was VAS pain rating at 24 hours. Secondary outcomes included pain ratings in the recovery room and at 48 hours, morphine consumption, the incidence of catheter dislodgments, procedure time, and block difficulty. Procedural data and all pain ratings were collected by blinded observers.

RESULTS

There were no differences in the primary outcome of median VAS pain rating at 24 hours between the out-of-plane and in-plane groups (1.50; IQR, [0 - 4.38] vs. 1.25; IQR, [0 - 3.75]; P = 0.57). There were also no differences, respectively, between out-of-plane and in-plane median PACU pain ratings (1.0; IQR, [0 - 3.5] vs. 0.25; IQR, [0 - 2.5]; P = 0.08) and median 48-hour pain ratings (1.25; IQR, [1.25 - 2.63] vs. 0.50; IQR, [0 - 1.88]; P = 0.30). There were no differences in any other secondary endpoint.

CONCLUSIONS

Our out-of-plane technique did not provide superior analgesia to the in-plane technique. It did not increase the number of complications. Our technique is an acceptable alternative in situations where the in-plane technique is difficult to perform.

Для цитирования: Schwenk Eric S, Gandhi Kishor, Baratta Jaime L, Torjman Marc, Epstein Richard H, Chung Jaeyoon, Vaghari Benjamin A, Beausang David, Bojaxhi Elird, Grady Bernadette. Ultrasound-Guided Out-of-Plane vs. In-Plane Interscalene Catheters: A Randomized, Prospective Study.. Anesthesiology and pain medicine. 2015. DOI: 10.5812/aapm.31111.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.