MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tbcas.2020.3008513

Медицинская библиотека · IEEE transactions on biomedical circuits and systems · 2020

Fully Integrated Time-Gated 3D Fluorescence Imager for Deep Neural Imaging.

Choi Jaebin, Taal Adriaan J, Meng William L, Pollmann Eric H, Stanton John W, Lee Changhyuk, Moazeni Sajjad, Moreaux Laurent C, Roukes Michael L, Shepard Kenneth L

СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПеревод в очереди

Аннотация

This paper presents a device for time-gated fluorescence imaging in the deep brain, consisting of two on-chip laser diodes and 512 single-photon avalanche diodes (SPADs). The edge-emitting laser diodes deliver fluorescence excitation above the SPAD array, parallel to the imager. In the time domain, laser diode illumination is pulsed and the SPAD is time-gated, allowing a fluorescence excitation rejection up to O.D. 3 at 1 ns of time-gate delay. Each SPAD pixel is masked with Talbot gratings to enable the mapping of 2D array photon counts into a 3D image. The 3D image achieves a resolution of 40, 35, and 73 μm in the x, y, and z directions, respectively, in a noiseless environment, with a maximum frame rate of 50 kilo-frames-per-second. We present measurement results of the spatial and temporal profiles of the dual-pulsed laser diode illumination and of the photon detection characteristics of the SPAD array. Finally, we show the imager's ability to resolve a glass micropipette filled with red fluorescent microspheres. The system's 420 μm-wide cross section allows it to be inserted at arbitrary depths of the brain while achieving a field of view four times larger than fiber endoscopes of equal diameter.

Для цитирования: Choi Jaebin, Taal Adriaan J, Meng William L, Pollmann Eric H, Stanton John W, Lee Changhyuk, Moazeni Sajjad, Moreaux Laurent C, Roukes Michael L, Shepard Kenneth L. Fully Integrated Time-Gated 3D Fluorescence Imager for Deep Neural Imaging.. IEEE transactions on biomedical circuits and systems. 2020. DOI: 10.1109/tbcas.2020.3008513.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.