MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/09593330.2012.701235

Медицинская библиотека · Environmental technology · 2013

Ultrasound irradiation combined with hydraulic cleaning on fouled polyethersulfone and polyvinylidene fluoride membranes.

Wan Meng-Wei, Reguyal Febelyn, Futalan Cybelle, Yang Hui-Ling, Kan Chi-Chuan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

In this study, an ultrasonic irradiation technique was utilized to mitigate the fouling of polyethersulfone (PES) and polyvinylidene fluoride (PVDF) membranes. The use of ultrasound at 20 kHz was applied to a dead-end microfiltration cell in order to mitigate fouling caused by the presence of colloidal bentonite particles. The effect of ultrasonic power and pulse duration on the permeate flux recovery was examined. Measurements indicate that an increase in ultrasonic power and longer pulse duration results to a higher permeate flux recovery. In order to reduce power consumption, a low to high power shift (LHPS) and pulsation method, were investigated. Methods of cleaning such as ultrasonic irradiation, ultrasonic cleaning with forward flushing and ultrasonic cleaning with backwashing were utilized and their cleaning efficiencies were examined. The cleaning performance was assessed using the clean water flux method and scanning electron microscope analysis of the cleaned membranes. Results showed that LHPS and pulsation method both improve the permeate flux recovery but were not able to attain the 93.97 and 74.88% flux recovery for PES and PVDF that was achieved by constant-15 W ultrasonic cleaning. In addition, forward flushing and backwashing may enhance the performance of ultrasonic cleaning at 9 W but could become disadvantageous at 15 W.

Для цитирования: Wan Meng-Wei, Reguyal Febelyn, Futalan Cybelle, Yang Hui-Ling, Kan Chi-Chuan. Ultrasound irradiation combined with hydraulic cleaning on fouled polyethersulfone and polyvinylidene fluoride membranes.. Environmental technology. 2013. DOI: 10.1080/09593330.2012.701235.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.