MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/bja/aeh010

Медицинская библиотека · British journal of anaesthesia · 2004

Endotoxaemia during left ventricular assist device insertion: relationship between risk factors and outcome.

O'Malley C M N, Frumento R J, Mets B, Naka Y, Bennett-Guerrero E

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Endotoxaemia, caused by splanchnic ischaemia during surgery, is believed to trigger systemic inflammation and cause postoperative organ dysfunction. A relationship between the plasma concentration of endotoxin during surgery and known risk factors for postoperative morbidity and mortality (e.g. age, abnormal gastric tonometric variables) and adverse outcome after surgery has not been demonstrated.

METHODS

In a prospective study, the plasma concentration of endotoxin was measured in 12 patients undergoing implantation of a left ventricular assist device. Automated air gastric tonometry was performed in all patients. The relationship between plasma endotoxin concentration, risk factors, and postoperative outcome was explored.

RESULTS

Carbon dioxide gap increased from 0.7 (0.3) to 3.6 (1.6) kPa at the end of surgery. Endotoxin was detected in one of 12 patients at baseline and in nine of 12 patients at the end of surgery (P=0.003). A high plasma concentration of endotoxin at the end of surgery was associated with a higher carbon dioxide gap (r=0.59, P<0.05), and a higher postoperative multiple organ dysfunction score (r=0.7, P=0.01).

CONCLUSIONS

The finding of an association between high intraoperative plasma concentrations of endotoxin, abnormal gastric tonometric variables and adverse outcome supports the view that endotoxaemia is caused by gut hypoperfusion during surgery and is associated with postoperative organ dysfunction.

Для цитирования: O'Malley C M N, Frumento R J, Mets B, Naka Y, Bennett-Guerrero E. Endotoxaemia during left ventricular assist device insertion: relationship between risk factors and outcome.. British journal of anaesthesia. 2004. DOI: 10.1093/bja/aeh010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.