MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10877-019-00354-4

Медицинская библиотека · Journal of clinical monitoring and computing · 2019

Feasibility evaluation of non-invasive cardiac function technology during echocardiography-based cardiac stress testing.

Ramsingh Davinder, Ma Michael, Kim Jin Kyung, Knoll Margaret, Patton John W, Cannesson Maxime

СтатьяПеревод в очереди

Аннотация

Evaluation of cardiac function during periods of stress is of key importance for the perioperative setting. Non-invasive hemodynamic monitors provide markers of cardiac function. This pilot study sought to evaluate the ability of a non-invasive hemodynamic monitor to detect cardiac stress during formal stress echocardiography testing. The primary goal was to compare the change in hemodynamic values during the pre/during/post phases of stress echocardiography testing in patients who had results negative versus positive for myocardial ischemia. Adult patients scheduled for outpatient cardiac stress testing were screened. Only patients scheduled for stress-echocardiography testing were consented. Patients with history of arrhythmias were excluded. During the testing, patients wore a cuff-based hemodynamic sensor (Nexfin system, Edwards Lifesciences). Data from the hemodynamic sensor were compared to the findings of the stress study. A total of 37 patients were enrolled, with 31 patients included for analysis. Five patients had stress studies positive for coronary ischemia. Comparison of the hemodynamic variables between patients who had a positive stress study versus negative showed a significant reduction in the percentage change in dP/dt and stroke volume from baseline (p < 0.05). This pilot study indicates that patients who have abnormal stress echocardiograms also have significantly reduced values from a noninvasive hemodynamic monitor. Further evaluation of the clinical utility of this technology, to assist in the care of patients at risk for cardiac ischemia, should be carried out.

Для цитирования: Ramsingh Davinder, Ma Michael, Kim Jin Kyung, Knoll Margaret, Patton John W, Cannesson Maxime. Feasibility evaluation of non-invasive cardiac function technology during echocardiography-based cardiac stress testing.. Journal of clinical monitoring and computing. 2019. DOI: 10.1007/s10877-019-00354-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.