MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.psj.2024.104452

Медицинская библиотека · Poultry science · 2024

Development and evaluation of three multienzyme isothermal rapid amplification assays for fowl adenovirus serotype 4.

Dai Yin, Zhong Yueyi, Xu Fazhi, Gu Siqin, Zhou Huiqin, Wang Jieru, Yin Dongdong, Yin Lei, Shen Xuehuai, Pan Xiaocheng, Liu Xuelan

СтатьяПеревод в очереди

Аннотация

Fowl adenovirus serotype 4 (FAdV-4) is the main causative agent of hydropericardium hepatitis syndrome (HHS), which has resulted in huge economic losses to the poultry industry in recent years. Hence, a rapid and simple visual detection method is needed for identification of FAdV-4. In this study, three multienzyme isothermal rapid amplification (MIRA) assays, basic MIRA, MIRA-qPCR and MIRA-LFD were developed for detection of FAdV-4. The amplification primers and reaction conditions were optimized, and the specificity and sensitivity of the assays were evaluated. The MIRA assays were specific for FAdV-4 with no cross-reaction with novel goose astrovirus, H9 subtype avian influenza virus, duck enteritis virus, Muscovy duck reovirus, or duck circovirus. The basic MIRA assay required only one primer pair and the reaction can be completed within 30 min at 36 °C. The MIRA-qPCR and MIRA-LFD assays were completed in 20 min with a minimum detection limit of 1 × 101 copies/μL and 1 × 102 copies/μL, respectively. The results of the MIRA-LFD assay can be observed directly with the naked eye, omitting the need for specialized instruments. The positive rate of three proposed MIRA assays were consistent with that of the conventional PCR assay. The MIRA assays are simple, rapid, and effective diagnostic tools for field detection of FAdV-4.

Для цитирования: Dai Yin, Zhong Yueyi, Xu Fazhi, Gu Siqin, Zhou Huiqin, Wang Jieru, Yin Dongdong, Yin Lei, Shen Xuehuai, Pan Xiaocheng, Liu Xuelan. Development and evaluation of three multienzyme isothermal rapid amplification assays for fowl adenovirus serotype 4.. Poultry science. 2024. DOI: 10.1016/j.psj.2024.104452.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.