Initial Experience of a Second-Generation Self-Expanding Transcatheter Aortic Valve: The UK & Ireland Evolut R Implanters' Registry.

Kalra Sundeep S, Firoozi Sami, Yeh James, Blackman Daniel J, Rashid Shabnam, Davies Simon, Moat Neil, Dalby Miles, Kabir Tito, Khogali Saib S, Anderson Richard A, Groves Peter H, Mylotte Darren, Hildick-Smith David, Rampat Rajiv, Kovac Jan, Gunarathne Ashan, Laborde Jean-Claude, Brecker Stephen J

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVES

The authors present the UK and Irish real-world learning curve experience of the Evolut R transcatheter heart valve.

BACKGROUND

The Evolut R is a self-expanding, repositionable, and fully recapturable second-generation transcatheter heart valve with several novel design features to improve outcomes and reduce complications.

METHODS

Clinical, procedural, and 30-day outcome data were prospectively collected for the first 264 patients to receive the Evolut R valve in the United Kingdom and Ireland.

RESULTS

A total of 264 consecutive Evolut R implantations were performed across 9 centers. The mean age was 81.1 ± 7.8 years, and the mean logistic European System for Cardiac Operative Risk Evaluation score was 19.9 ± 13.7%. Procedural indications included aortic stenosis (72.0%), mixed aortic valve disease (17.4%), and failing aortic valve bioprostheses (10.6%). Conscious sedation was used in 39.8% of patients and transfemoral access in 93.6%. The procedural success rate was 91.3%, and paravalvular leak immediately after implantation was mild or less in 92.3%. Major complications were rare: cardiac tamponade in 0.4%, conversion to sternotomy in 0.8%, annular rupture in 0.0%, coronary occlusion in 0.8%, major vascular in 5.3%, acute kidney injury in 6.1%, new permanent pacemaker implantation in 14.7%, and procedure-related death in 0.0%. At 30-day follow-up, survival was 97.7%, paravalvular leak was mild or less in 92.3%, and the stroke rate was 3.8%.

CONCLUSIONS

This registry represents the largest published real-world experience of the Evolut R valve. The procedural success rate was high and safety was excellent, comparable with previous studies of the Evolut R valve and other second-generation devices. The low rate of complications represents an improvement on first-generation devices.

Для цитирования: Kalra Sundeep S, Firoozi Sami, Yeh James, Blackman Daniel J, Rashid Shabnam, Davies Simon, Moat Neil, Dalby Miles, Kabir Tito, Khogali Saib S, Anderson Richard A, Groves Peter H, Mylotte Darren, Hildick-Smith David, Rampat Rajiv, Kovac Jan, Gunarathne Ashan, Laborde Jean-Claude, Brecker Stephen J. Initial Experience of a Second-Generation Self-Expanding Transcatheter Aortic Valve: The UK & Ireland Evolut R Implanters' Registry.. JACC. Cardiovascular interventions. 2017. DOI: 10.1016/j.jcin.2016.11.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.