MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40779-021-00319-2

Медицинская библиотека · Military Medical Research · 2021

Hemopneumothorax detection through the process of artificial evolution - a feasibility study.

Sommer Adir, Mark Noy, Kohlberg Gavriel D, Gerasi Rafi, Avraham Linn Wagnert, Fan-Marko Ruth, Eisenkraft Arik, Nachman Dean

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Tension pneumothorax is one of the leading causes of preventable death on the battlefield. Current prehospital diagnosis relies on a subjective clinical impression complemented by a manual thoracic and respiratory examination. These techniques are not fully applicable in field conditions and on the battlefield, where situational and environmental factors may impair clinical capabilities. We aimed to assemble a device able to sample, analyze, and classify the unique acoustic signatures of pneumothorax and hemothorax.

METHODS

Acoustic data was obtained with simultaneous use of two sensitive digital stethoscopes from the chest wall of an ex-vivo porcine model. Twelve second samples of acoustic data were obtained from the in-house assembled digital stethoscope system during mechanical ventilation. The thoracic cavity was injected with increasing volumes of 200, 400, 600, 800, and 1000 ml of air or saline to simulate pneumothorax and hemothorax, respectively. The data was analyzed using a multi-objective genetic algorithm that was used to develop an optimal mathematical detector through the process of artificial evolution, a cutting-edge approach in the artificial intelligence discipline.

RESULTS

The in-house assembled dual digital stethoscope system and developed genetic algorithm achieved an accuracy, sensitivity and specificity ranging from 64 to 100%, 63 to 100%, and 63 to 100%, respectively, in classifying acoustic signal as associated with pneumothorax or hemothorax at fluid injection levels of 400 ml or more, and regardless of background noise.

CONCLUSIONS

We present a novel, objective device for rapid diagnosis of potentially lethal thoracic injuries. With further optimization, such a device could provide real-time detection and monitoring of pneumothorax and hemothorax in battlefield conditions.

Для цитирования: Sommer Adir, Mark Noy, Kohlberg Gavriel D, Gerasi Rafi, Avraham Linn Wagnert, Fan-Marko Ruth, Eisenkraft Arik, Nachman Dean. Hemopneumothorax detection through the process of artificial evolution - a feasibility study.. Military Medical Research. 2021. DOI: 10.1186/s40779-021-00319-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.