Continuous Blood Gas Control Based on Active Disturbance Rejection Control During Ex Vivo Porcine Liver Perfusion.
Аннотация
BACKGROUND
Membrane oxygenators facilitate extracorporeal gas exchange, necessitating the monitoring of blood gas. Recent advances in normothermic machine perfusion (NMP) for ex vivo liver offer solutions to the shortage of donor liver. However, maintaining physiological blood gas levels during prolonged NMP is complex and costly.
METHODS
We introduce a noninvasive and economical approach for regulating the blood gas during NMP of ex vivo porcine livers. By monitoring gas fractions at the outlet of oxygenator, real-time adjustments of blood gas can be made without the online blood gas analyzer. The method involves constructing multivariate linear regression (MLR) models, aligning target setpoints of gas, and employing active disturbance rejection control (ADRC) to achieve closed-loop regulation.
RESULTS
Ex vivo porcine liver perfusion experiments demonstrated the effectiveness of the method, maintaining blood gas within physiological levels over 24 h (oxygen partial pressure: 150.36 ± 3.33 mmHg, carbon dioxide partial pressure: 41.34 ± 0.91 mmHg).
CONCLUSION
ADRC-based continuous regulation of gas fraction at the outlet of oxygenator is a feasible and effective approach for managing blood gas during ex vivo porcine liver perfusion.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.