Drug metabolism and bioanalysis letters · 2024
Bioactive Formulation and Bulk Allopurinol and Lycopene Estimation by UV Spectroscopy.
СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mishra Soumya, Harwansh Ranjit K, Mazumder Rupa
Аннотация
BACKGROUND: This study developed a UV spectrophotometric method for quantifying allopurinol and lycopene in both bulk and dosage forms, aiming for simplicity and practicality.
MATERIALS AND METHODS: The method was developed and validated using methanol and lycopene in phosphate buffer saline at various pH levels (7.4, 6.8, 1.2, 5.5). Validation parameters included linearity, accuracy, precision, limit of quantification (LOQ), and limit of detection (LOD) according to ICH standards.
RESULTS: The method demonstrated high sensitivity and linearity over a concentration range of 4-20 μg/ml, adhering to Beer's law. The LOQ and LOD were 2-18 μg/ml and 2-6 μg/ml, respectively. Optimal absorbance wavelengths were 251 nm for lycopene and 471 nm for allopurinol. Calibration curves showed a high correlation coefficient (0.9994), indicating a strong linear relationship.
CONCLUSION: The developed UV spectrophotometric method is effective, interference-free, and suitable for routine quality control, providing reliable measurements for allopurinol and lycopene.
MATERIALS AND METHODS: The method was developed and validated using methanol and lycopene in phosphate buffer saline at various pH levels (7.4, 6.8, 1.2, 5.5). Validation parameters included linearity, accuracy, precision, limit of quantification (LOQ), and limit of detection (LOD) according to ICH standards.
RESULTS: The method demonstrated high sensitivity and linearity over a concentration range of 4-20 μg/ml, adhering to Beer's law. The LOQ and LOD were 2-18 μg/ml and 2-6 μg/ml, respectively. Optimal absorbance wavelengths were 251 nm for lycopene and 471 nm for allopurinol. Calibration curves showed a high correlation coefficient (0.9994), indicating a strong linear relationship.
CONCLUSION: The developed UV spectrophotometric method is effective, interference-free, and suitable for routine quality control, providing reliable measurements for allopurinol and lycopene.