Temporal assessment of pancreatic blood flow and perfusion following secretin stimulation using noninvasive MRI.

Cox Eleanor F, Smith Janette K, Chowdhury Abeed H, Lobo Dileep N, Francis Susan T, Simpson John

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To dynamically quantify pancreatic perfusion and flow within the arteries supplying the pancreas in response to secretin stimulation.

MATERIALS AND

METHODS

Twelve healthy male subjects were scanned at 1.5T with arterial spin labeling to measure tissue perfusion and phase contrast magnetic resonance imaging (MRI) to measure vessel flow. Superior mesenteric (SMA), gastroduodenal (GDA), common hepatic (HA), and splenic (SA) arterial flow and pancreatic perfusion were serially measured for 50 minutes following 1 IU/kg intravenous secretin. The significance of differences between timepoints was tested using a repeated measures one-way analysis of variance (ANOVA).

RESULTS

Baseline blood flow (mean ± SEM or median [IQR]) for SMA, HA, SA, and GDA was 7.6 ± 1.3, 4.0 ± 0.5, 8.2 ± 0.8, and 0.9 (0.8-1.4) ml/s, respectively. Baseline pancreatic perfusion was 200 ± 25 ml/100g/min. Blood flow increased in the SMA (234%, P < 0.0001) and GDA (155%, P = 0.015) immediately after secretin injection. Reduced HA blood flow was observed after 10 minutes (P = 0.066) with no change in SA flow (P = 0.533). Increased pancreatic perfusion was maintained for 40 minutes after injection with a maximal increase at 5 minutes (16.8%, P = 0.025).

CONCLUSION

Intravenous secretin resulted in significant temporal changes in pancreatic perfusion and arterial blood flow.

Для цитирования: Cox Eleanor F, Smith Janette K, Chowdhury Abeed H, Lobo Dileep N, Francis Susan T, Simpson John. Temporal assessment of pancreatic blood flow and perfusion following secretin stimulation using noninvasive MRI.. Journal of magnetic resonance imaging : JMRI. 2015. DOI: 10.1002/jmri.24889.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.