Automated high-capacity on-line extraction and bioanalysis of dried blood spot samples using liquid chromatography/high-resolution accurate mass spectrometry.

Oliveira Regina V, Henion Jack, Wickremsinhe Enaksha R

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

RATIONALE: Pharmacokinetic data to support clinical development of pharmaceuticals are routinely obtained from liquid plasma samples. The plasma samples require frozen shipment and storage and are extracted off-line from the liquid chromatography/tandem mass spectrometry (LC/MS/MS) systems. In contrast, the use of dried blood spot (DBS) sampling is an attractive alternative in part due to its benefits in microsampling as well as simpler sample storage and transport. However, from a practical aspect, sample extraction from DBS cards can be challenging as currently performed. The goal of this report was to integrate automated serial extraction of large numbers of DBS cards with on-line liquid chromatography/high-resolution accurate mass spectrometry (LC/HRAMS) bioanalysis.

METHODS

An automated system for direct DBS extraction coupled to a LC/HRAMS was employed for the quantification of midazolam (MDZ) and α-hydroxymidazolam (α-OHMDZ) in human blood. The target analytes were directly extracted from the DBS cards onto an on-line chromatographic guard column followed by HRAMS detection. No additional sample treatment was required. The automated DBS LC/HRAMS method was developed and validated, based on the measurement at the accurate mass-to-charge ratio of the target analytes to ensure specificity for the assay.

RESULTS

The automated DBS LC/HRAMS method analyzed a DBS sample within 2 min without the need for punching or additional off-line sample treatment. The fully automated analytical method was shown to be sensitive and selective over the concentration range of 5 to 2000 ng/mL. Intra- and inter-day precision and accuracy was less than 15% (less than 20% at the LLOQ). The validated method was successfully applied to measure MDZ and α-OHMDZ in an incurred human sample after a single 7.5 mg dose of MDZ.

CONCLUSIONS

The direct DBS LC/HRAMS method demonstrated successful implementation of automated DBS extraction and bioanalysis for MDZ and α-OHMDZ. This approach has the potential to promote workload reduction and sample throughput increase.

Для цитирования: Oliveira Regina V, Henion Jack, Wickremsinhe Enaksha R. Automated high-capacity on-line extraction and bioanalysis of dried blood spot samples using liquid chromatography/high-resolution accurate mass spectrometry.. Rapid communications in mass spectrometry : RCM. 2014. DOI: 10.1002/rcm.7033.