MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2340/1651-226x.2025.42249

Медицинская библиотека · Acta oncologica (Stockholm, Sweden) · 2025

Self-measured leg circumference for the detection of lymphedema among men with prostate cancer: a reliability study.

Larsen Gitte Sone, Jensen Sandra, Von Heymann Annika, Rafn Bolette Skjødt

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Early lymphedema detection is crucial to timely treatment, and home-based monitoring holds promise for early detection of leg lymphedema among at-risk cancer survivors. We developed a self-measurement protocol for home-based leg circumference measurements and tested its reliability in men with prostate cancer at risk of lymphedema.

PATIENTS/MATERIAL AND

METHODS

This cross-sectional study recruited men with prostate cancer from the Department of Urology, Copenhagen University Hospital, Denmark. Circumference measurements were taken at four points on both legs, from which leg volume was calculated. Intrarater reliability was assessed by comparing self-measurements taken at home and in the hospital. Interrater reliability was evaluated by comparing hospital self-measurements to those of a blinded physiotherapist. Statistical power required 13 participants for the detection of a good (>0.8) intraclass correlation coefficient (ICC).

RESULTS

Forty-three men were included (median age 69 [63-76] years). Intrarater reliability (n = 39) was good to excellent for six out of eight measurement points (ICC ≥ 0.79, p < 0.01) and moderate for two (ICC ≥ 0.55, p < 0.01). Intrarater reliability for leg volume was excellent (ICC ≥ 0.96, p < 0.01). Similarly, interrater reliability (n = 23) was excellent for all measurement points and leg volumes (ICC ≥ 0.91, p < 0.01). Forty-one of 43 participants performed the measurements independently, found them easy to do, and were willing to conduct self-measurements if recommended by their doctor.

INTERPRETATION: Self-measured leg circumference among men with prostate cancer is highly reliable and acceptable. This low-cost approach for home-based monitoring for lymphedema offers potential for early detection and timely management of the condition.

Для цитирования: Larsen Gitte Sone, Jensen Sandra, Von Heymann Annika, Rafn Bolette Skjødt. Self-measured leg circumference for the detection of lymphedema among men with prostate cancer: a reliability study.. Acta oncologica (Stockholm, Sweden). 2025. DOI: 10.2340/1651-226x.2025.42249.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.