Health System Redesign of Cardiac Monitoring Oversight to Optimize Alarm Management, Safety, and Staff Engagement.

Engel Jill R, Lindsay Mary, O'Brien Stacey, Granger Christopher B, Moore Eric S, Hughes Tracey, Parker Carley, Miller Corinne, Fuchs Mary Ann

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this quality improvement project was to improve health system patient safety by creating a cardiac monitoring structure aligned with national standards.

BACKGROUND

Excessive alarms pose patient safety threats and are often false or clinically insignificant. The Joint Commission identified reduction of nonactionable alarms as a National Patient Safety Goal.

METHODS

The conversion to structured monitoring occurred in 4 phases: 1) defining health system monitoring structure and processes; 2) co-create sessions; 3) implementation and impact analysis; and 4) ongoing evaluation and optimization.

RESULTS

Twenty-two clinical units participated. At the conclusion of phase 4, total 30-day alarm rates decreased by 74% at the academic hospital and by 92% and 95% at the community hospitals and were sustained for 12 months.

CONCLUSIONS

Decreasing alarm frequency can be safely achieved in academic and community hospitals by creating a system-wide monitoring infrastructure and standardized processes that engage interdisciplinary teams.

Для цитирования: Engel Jill R, Lindsay Mary, O'Brien Stacey, Granger Christopher B, Moore Eric S, Hughes Tracey, Parker Carley, Miller Corinne, Fuchs Mary Ann. Health System Redesign of Cardiac Monitoring Oversight to Optimize Alarm Management, Safety, and Staff Engagement.. The Journal of nursing administration. 2022. DOI: 10.1097/nna.0000000000001192.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.