MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jon.12641

Медицинская библиотека · Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2019

Multicenter Volumetric Assessment of Artifactual Hypoperfusion Patterns using Automated CT Perfusion Imaging.

Siegler James E, Olsen Andrew, Pulst-Korenberg Johannes, Cristancho Daniel, Rosenberg Jon, Raab Lindsay, Cucchiara Brett, Messé Steven R

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Automated computed tomography perfusion (CTP) is recommended to inform selection of stroke patients for thrombectomy >6 hours from last known normal (LKN). However, artifacts on automated perfusion output may overestimate the tissue at risk leading to misclassification of thrombectomy eligibility in some patients.

METHODS

We conducted a retrospective multisite study of consecutive patients with anterior large vessel occlusion (LVO) undergoing CTP (6/2017-12/2017). The primary outcome was the RAPID automated Tmax  > 6 seconds volume that was discordant with clinical symptoms and vessel imaging, manually assessed by two independent readers. The discordant penumbral volume was compared to the automated output and corrected mismatch ratios were generated.

RESULTS

Of 410 consecutive patients who underwent CTP for suspected stroke, 60 (15%) had acute anterior circulation LVO. Of these, 26 (43%) had Tmax > 6 seconds abnormalities discordant with clinical symptoms and vessel imaging. There was strong interrater agreement on artifact volume (r2 = 0.927). Among patients with discordant Tmax imaging, the median artifactual volume was 12cc (IQR 3-21cc), accounting for a median of 8% of the automated Tmax > 6 seconds volume (IQR 3-16%, range 1-64%). Recalculation of the Tmax > 6 seconds volume resulted in 1 patient being reclassified as having an "unfavorable" mismatch ratio (2.04-1.40).

CONCLUSION

Nearly half of patients had evidence of artifactual penumbral imaging on automated CTP, which rarely lead to misclassification of thrombectomy eligibility. Although artifactual findings are reliably identified by trained raters, our results emphasize the need to evaluate CTP results with knowledge of the patient's clinical symptoms and vascular imaging.

Для цитирования: Siegler James E, Olsen Andrew, Pulst-Korenberg Johannes, Cristancho Daniel, Rosenberg Jon, Raab Lindsay, Cucchiara Brett, Messé Steven R. Multicenter Volumetric Assessment of Artifactual Hypoperfusion Patterns using Automated CT Perfusion Imaging.. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2019. DOI: 10.1111/jon.12641.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.